Herunterladen Diese Seite drucken

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
GB
Installation
Remove fitting template.
Flush pipes thoroughly.
Note:
First fit the diverter (A) before installing head-
part 19 026, see fold-out page I, Fig. [1].
1. Remove screw plug (B).
2. Screw diverter (A) into position using 17mm socket
spanner and tighten.
Scalding protection possible by fitting a temperature
limiter (see replacement parts fold-out page II, ref.
No. 46 308).
Flow rate limiter
This mixer is fitted with a flow rate limiter, permitting an
infinitely individual variable reduction in the flow rate.
The highest possible flow rate is set by the factory
before despatch.
The use of flow rate limiters in combination with
hydraulic instantaneous water heaters is not
recommended.
For commissioning see Fig. [2].
Install escutcheon and lever, see Figs. [3] and [4].
• Screw on cap (C), see Fig. [3].
• Grease seals (D1) and (D2).
• Push on escutcheon mounting base (D) and secure
with screws (E).
• Clip escutcheon (G) into escutcheon mounting
base (D).
• Fit insulator (H) onto cartridge actuating lever and fit
screw (J), see Fig. [4].
• Strip lever lower part (K) and push on lever (L).
• Fit lever (L), secure by tightening the loosely fitted
set screw (M) with 3mm socket spanner and lift up
lever lower part (K).
If the escutcheon will not slide far enough onto the
cap, you must additionally install an extension
(46 191 = 25mm / 46 343 = 50mm), see replacement
parts on fold-out page II.
Additionally seal the top edge of the escutcheon with
silicone if it is fitted against a particularly rough surface
(deep tile joints, highly textured tile).
Check mixer operation
Pull lever
= open (water flow)
Press lever down
= closed
Turn lever right
= cold water
Turn lever left
= hot water
Check operation of automatic diverter (A),
see fold-out page III, Fig. [5].
Pulling the lever will release water delivery.
On the bath mixer, water will always emerge from the
lower outlet first (i.e. bath spout).
Pressing diverter (A) will close the flow of water to the
bath and deliver water to the shower outlet.
On turning off the mixer, the diverter will be released
automatically so that when the mixer is turned on
again, water will always emerge from the lower outlet
first (i.e. bath outlet).

Maintenance

Inspect and clean all parts, replace as necessary and
grease with special grease (order no. 18 012).
Shut off the cold and hot water supply!
I. Cartridge, see Figs. [6] to [8].
1. Strip lever lower part (K), see Fig. [6].
2. Remove set screw (M) using a 3mm socket spanner
and pull off lever (L), see Fig. [7].
3. Remove escutcheon (G) as shown in Fig. [8].
4. Remove screws (E) and pull off mounting base (D),
see Fig. [7].
5. Unscrew cap (C).
6. Remove screws (N) and detach cartridge (P).
7. Replace complete cartridge (P).
Assemble in reverse order.
Make sure that the cartridge seals engage in the
grooves on the housing. Fit screws (N) and tighten
evenly and alternately.
II. Diverter, see Figs. [7] and [9].
1. Same procedure as steps 1 - 6 for cartridge
maintenance.
2. Unscrew diverter (A), see Fig. [7].
3. Hold pushbutton (R) with rubber protected pliers,
pull out diverter plunger (S) and unscrew diverter
spindle (T) from the diverter housing (U) using a
4mm open-ended spanner, see Fig. [9].
Assemble in reverse order.
Replacement parts, see fold-out page II ( * = special
accessories).
Care
For directions on the care of this fitting, please refer to
the accompanying Care Instructions.
2

Werbung

loading

Diese Anleitung auch für:

Eurosolid 19 000