To protect the pump, the machine uses a software-based fluid sensor to test if there is fog fluid in the tube. This
function can be activated ("on") and deactivated ("off") under the menu item "Fluid Sensor".
If the sensor detects not enough fluid in the tube, the machine will enter a protection mode after about 60 seconds
and shuts the pump down. The display will start flashing. There are three possibilities to release the sensor after
having refilled fluid:
• Keep the ENTER button pressed until fluid is flowing through the tube again.
• In DMX mode, set the fog output to a value between 0 and 5 and then to a value between 6 and 255, so that fluid
will flow through the tube.
• Deactivate the fluid sensor via the menu setting "Fluid Sensor" > "off".
Note
• The fluid sensor is a very important protection mechanism. For proper operation, it should be activated.
We recommend a frequent cleaning of the unit, in particular the output nozzle. Please use a soft lint-free and
moistened cloth for the outside of the unit. Never use alcohol or solvents! Do not allow the fog liquid to become
contaminated. Always replace the caps on the fog liquid container and the fog machine liquid tank immediately
after filling.
There are no serviceable parts inside the device. Maintenance and service operations are only to be carried out by
authorized dealers. Should you need any spare parts, please use genuine parts. If defective, please dispose of the
unusable device in accordance with the current legal regulations. Should you have further questions, please
contact your dealer.

Fuse

The machine is fitted with a circuit breaker. In the unlikely event of overloading, the circuit breaker will
automatically trip. It can be reset by pressing the BREAKER button with the machine unplugged.

Cleaning the heating element

The heating element should regularly be cleaned every 40 operational hours in order to avoid clogging. Use fog
machine cleaner available at your dealer. All fog machines are prone to clogging due to the thick consistency of
fog liquid and the high temperature at which it vaporizes. However, a properly maintained fog machine should
provide years of reliable use.
Procedure:
• Fill cleaner into empty tank. Run the machine several times in a well-ventilated room only. The number of
repetitions depends on the pollution level of the vaporizing elements.
• After use, clean all remaining cleaner and rinse the tank thoroughly.
• The Eurolite fog fluids we recommend are non-hazardous to the environment and can be disposed of via the
sewage system.

Storage

It is recommended to operate the machine at least once a month with a warm-up period and a few minutes of fog
emission. Prior to storage, run cleaning fluid through the system as described in the cleaning regimen above. This
will help avoid any particles condensing inside the pump or heater.

FLUID SENSOR

CLEANING AND MAINTENANCE

21 • EN