Making the connections

The unit features 3-pin XLR plugs for DMX connection.
• Connect the output of your DMX controller to the DMX IN jack of the machine with a DMX cable.
• Connect the DMX OUT jack of the machine to the DMX input of the next unit in the chain. Always connect one
output to the input of the next unit until all units are connected.
• At the last unit, the DMX cable has to be terminated. Plug the terminator with a 120 Ω resistor between Signal (–)
and Signal (+) in the DMX output of the last unit.
• If the cable length exceeds 300 m or the number of DMX devices is greater than 32, it is recommended to insert
a DMX level amplifier to ensure proper data transmission.
Occupation of the XLR connection:

DMX functions

For operation with a controller with DMX512 protocol, the machine is equipped with 2 control channels.
Channel
1
2

Adjusting the DMX start address

When the machine is controlled via DMX signal, DMX mode is activated. The display indicates the current DMX
start address. To ensure that the control signals are properly directed to the machine, it must be adjusted to the
DMX start address provided for it on the DMX controller. Use the buttons ▲ and ▼ to set the address between
001 and 511. You may now start operating the machine via your DMX controller.
Note
• Please make sure that you do not have any overlapping channels in order to control each device correctly and
independently from any other fixture on the DMX data link. If two, three or more devices are addressed similarly,
they will work similarly.

Fluid sensor

To protect the pump, the machine uses a fluid sensor to test if there is fog fluid in the tube. If the fog output is
more than 50 % and the sensor detects not enough fluid in the tube, the machine will enter a protection mode
after about 5 minutes and shuts the pump down. The display will start flashing. There are two possibilities to
release the sensor after refilling fluid.
• Use the VOLUME control to initially set the fog output to "0", then set it to "100". After about 2 minutes, the
display will stop flashing and fluid will flow through the tube.
• In DMX mode, the procedure is similar. First set the fog output in channel 2 to "OFF" (0-10) and then to "ON"
(11-2559, so that fluid will flow through the tube after about 2 minutes.

DMX CONTROL

DMX value
0–10
11–255
0–10
11–255
Function
Fan off
Fan speed slow > fast
No fog output
Fog output low > high