Herunterladen Diese Seite drucken

Outline Diagram - Nibe EMK 310 Installateurhandbuch

Energiemesskit für vvm 310
Vorschau ausblenden Andere Handbücher für EMK 310:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

English, Installer manual - EMK 310
General
This accessory is used to measure the amount of energy
produced by and supplied by the heating installation
for hot water and heating in the building.
The function of the energy meter is to measure flow
and temperature difference in the charge circuit. The
value is shown on VVM 310's display.
Contents
1 x
Flow meter
1 x
Cable to flow meter
2 x
Connection kit (Lock spring and O-ring)
6 x
O-ring
1 x
Locking clips
2 x
Brass pipe connection nipple
1 x
Pipe with insulation

Outline diagram

Explanation
CM1
Expansion vessel closed, heating medium
BF1
Flow sensor, EMK 310
EB15
Indoor module (VVM 310)
EB101
Heat pump
FL2
Safety valve, heating medium
XL1
Connection, heating medium, flow
XL2
Connection, heating medium, return
XL8
Connection, docking in heating medium from heat
pump
XL9
Connection, docking, out heating medium to heat
pump
Designations according to standard IEC 61346-2.
Outline diagram EMK 310 with VVM 310
Note! This is an outline diagram. Actual installations
must be planned according to applicable standards.
-EB101
-FL10
-EB101
-RN10
-QM40
XL1
-HQ1
-QM41
XL2
-QM1
-FL2
-CM1
-XL8
-XL9
-EB15
BF1
GB
9

Werbung