Daily Inspection

Visual inspection:
1
Seal is undamaged.
— The lid is closed and the handle
is locked.
— There are no signs of cracks,
holes or other damages of more
than 1.5 mm depth on the
housing.
2
The indicator is dark blue in
colour.
The oxygen self-rescuer may no
longer be used if there is a significant loss of blue colour (50 % of
the particles have changed colour from dark blue to pink or
colourless).
Please contact Dräger if this is the case.

Assembly of Shoulder Strap

Oxy K 30 S (GB) and Oxy K 50 S (K+S)
To prepare the oxygen self-rescuer for use, mount the shoulder strap
as shown:
Looping the shoulder strap into
the back plate of the housing
Loop the short end of the
shoulder strap into the slot in the
housing's back plate (1).
Looping the shoulder strap into
the adjusting buckle
Thread the ends of the shoulder
straps into the adjusting buckles
and pull the ends of the shoulder
straps as far as possible (2).
Close the adjusting buckles(3).

Using the Oxygen Self-Rescuer

— Open the oxygen self-rescuer only in case of emergency.
If opened prematurely, the humidity of the ambient air could
penetrate the open oxygen self-rescuer and impair its function.
— Inspect the oxygen self-rescuer daily.
— Use the oxygen self-rescuer only once.
— To avoid risk of fire, make sure that no flammable materials
(petrol, grease, solvents etc.) can get into the oxygen self-rescuer
before or during operation.
There is also danger of ignition if the oxygen-releasing chemicals
come into contact with combustible substances such as coal
when the oxygen self-rescuer is damaged.
Opened units are classified as used and it is not allowed to store
them. They have to be disposed of (see "Disposal" on page 12).
For routine training purposes, use the training unit
Oxy K 30 DT/ET, Oxy K 50 ST or Oxy K 50 ST (PL) (see "Order List"
on page 15).
1) not part of the EC type examination.

Donning Procedure

If incorrectly donned in cases of emergency, the oxygen self-rescuer
2
could start up with a delay.
When donning the unit, follow the described order of steps.
1
Oxy K 30 E
Opening the housing
1
Donning the unit
2
3
Oxy K 30 S (GB) and Oxy K 50 S (K+S)
Opening the housing
Donning the unit
1)
Oxy K 30 ST,
Use the yellow grip to pull the unit
forwards.
Move the handle downwards
until the lid comes off of the
oxygen self-rescuer.
Remove lid.
Take hold of the neck strap with
one hand, then use your other
hand to take hold of the carrying
frame before pulling the oxygen
self-rescuer upwards and out of
the holder.
Turn the oxygen self-rescuer so
that the carrying frame faces the
chest.
Pull the red rubber neck band
over your head and let it hang
from the back of your neck.
Adjust the neck strap to pull the
oxygen self-rescuer into the
correct position.
Take hold of the yellow opener.
Push the yellow opener away
from your body until lid separates
from the oxygen self-rescuer.
Pull the lid straight off of the
oxygen self-rescuer (away from
your body).
Adjust the shoulder strap around
your neck.
Pull both shoulder straps as far
as they will go.
11