Herunterladen Inhalt Inhalt Diese Seite drucken

Protection Fuses - GiBiDi SR100 Installationsanleitung

Vorschau ausblenden Andere Handbücher für SR100:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 30
SR100

PROTECTION FUSES

Position
Value
F1
500 mA
F2
5 A
FUNCTIONS PROGRAMMING ( DIP SWITCH DIP1)
The settings are memorized during the pause phase (door closed).
DIP
Status
Function
ON
DIP 1
OFF
LEARNING
DIP 2
OFF
STEP – STEP
DIP 3
STOP STOP
OFF
ON
DIP 2
STEP - STEP
DIP 3
OFF
DIP 2
OFF
CONDOMINIUM
DIP 3
ON
ON
DIP 2
NOT ENABLED
DIP 3
ON
ON
EXTERNAL
DIP 4
COMMANDS
MANAGEMENT
OFF
DIP 5
OFF
DIP 8
ININFL.
DIP 5
ON
OFF
DIP 8
RADIO INPUT
MANAGEMENT
DIP 5
ON
DIP 8
ON
Type
Description
Accessories power supply input protection
RAPIDO
Board protection on 230 Vac power supply input
RAPIDO
Description
Enables the time learning procedure
TIME
Normal functioning
I Start pulse: OPENS
II Start pulse: STOPS (it will not close automatically)
III Start pulse: CLOSES
IV Start pulse: STOPS
I Start pulse: OPENS
II Start pulse: CLOSES
III Start pulse: OPENS
During opening, it does not receive other START commands after the first one, in
pause other START commands reload the pause time.
I Start pulse: OPENS
Next Start pulses: uninfluential
Pause from FCA or end of opening time
Start pulse during pause: reloads pause time (if automatic closing is enabled)
Start pulse during closing: OPENS
The keys GENERAL_OPEN and GENERAL_CLOSE work with DEAD MAN logic.
Keeping the key pressed, the motion stops for one second and then the manoeuvre
starts.
The key GENERAL_OPEN manages only opening. Keeping the key pressed, the
motion stops for one second and then the manoeuvre starts.
The key GENERAL_CLOSE manages only the closing. Keeping the key pressed, the
motion stops for one second, then the manoeuvre starts.
Channel 1 transmitter: opens
Channel 3 transmitter: closes
Channel 2 and 4 transmitter: stops the motion
The control unit recognizes only one radio input set with the DIP 6 and 7
The control unit recognizes only one radio input set with the DIP 6 and 7 but:
the continuous pressure for 3 s on the channel 1 of the transmitter manages the
opening of ALL the control units on which the transmitter is memorized;
the continuous pressure for 3 s on the channel 3 of the transmitter manages the
closing of ALL the control units on which the transmitter is memorized.
or CLOSES (if automatic closing is disabled)
11
UK

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis