Default Settings - GiBiDi SR100 Installationsanleitung

Vorschau ausblenden Andere Handbücher für SR100:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 30
12
UK
DIP
Status
DIP 6
OFF
DIP 7
OFF
DIP 6
OFF
DIP 7
ON
RADIO CHANNELS
DIP 6
ON
DIP 7
OFF
DIP 6
ON
DIP 7
ON
DIP 9
OFF
DIP 10
OFF
DIP 9
OFF
DIP 10
ON
DIP 9
ON
DIP 10
OFF
DIP 9
ON
DIP 10
ON

DEFAULT SETTINGS

9 3
DIP 1 ÷ 10 all OFF
8K2
EDGE INTERNAL RESISTANCE
If the 8K2 external resistor is always in parallel to the edge, the intervention of the same edge is recognized as limit
switch.
Function
Description
Channel 1 of the transmitter works as START.
Channel 2 of the transmitter works as START.
SETTING
Channel 3 of the transmitter works as START.
Channel 4 of the transmitter works as START.
It sets the SAF input as STOP with contact NC.
In case of intervention:
door closed: the control unit does not open;
in opening: it stops the motion and the next START will cause the closing;
in pause: it does not allow closing and the next start will cause the closing;
in closing: it stops the motion and the next start will cause the opening.
It sets the SAF input as STOP with contact NO.
In case of intervention:
Doro closed: the control unit does not open;
in opening: it stops the motion and the next start will cause the closing;
in pause: it does not allow closing and the next start will cause closing;
in closing: it stops the motion and the next start will cause the opening.
Please make sure that the dip STOP NC is on OFF.
It sets the SAF input as 8K2 EDGE WITHOUT LIMIT SWITCHES.
SAFETY INPUT
In case of intervention:
MANAGEMENT
door closed: the control unit does not open;
in opening: stop and motion inversion for 2 s. at next start pulse the motion starts in
the obstacle-freeing direction;
in pause: it does not allow closing and the next start will cause closing;
in closing: stop and motion inversion for 2 s. At next start pulse the motion restarts
in the obstacle-freeing direction.
It sets the SAF input as 8K2 EDGE WITH LIMIT SWITCHES.
The functioning is the same as the previous point, but with possibility of reading the
limit switches switch
The enabling of this switch before the edge activation is recognized as limit switch.
In this case, the control unit is not blocked because of the edge intervention.
It is necessary that the switch connects in parallel to the 8K2 internal resistor of the
edge another one having the same value. (3)
SENSITIVE EDGE
CONNECTION TO THE
SR100 CONTROL UNIT
SR100
ADDITIONAL 8K2 RESISTANCE
LIMIT SWITCH ASEMBLED
NEAR THE CLOSING