Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 100
30
UK

PROTECTION FUSES

Position
Value
F1
10 A
F2
10 A
F3
500 mA
PROGRAMMING PROCEDURE AND SYSTEM CONFIGURATION
The system adjustments can be accessed via the display. There are 5 different menus marked with the
letters A, C, F, H and E.
-
ESC
-
ESC
-
ESC
-
ESC
Type
Description
Accessories and motor protection, power supply from battery charger circuit.
/
/
Equipment, motor and safety devices protection.
FAST
Accessories protection.
Gbd
+
OK
PASS
+
OK
0 0 0 0
+
OK
4 0 0 0
+
OK
1
To enter the programming procedure:
- start from the display as is shown in the picture
- Press simultaneously the keys ESC and OK for 3 seconds
(The writing Gbd will turn off)
2
The writing P A S S appears on the display.
Press the OK button to go to step 3.
Press the ESC button to exit and return to step 1.
3 3
3 3
4 figures appear on the display ( 0 0 0 0 ), the first one is flashing.
With the + or – keys, the user selects the first digit of the installer
code.
When the required digit is selected, press the OK key to confirm
and go to step 4.
4
The second figure is flashing.
With the + or – keys, the user selects the second digit of the
installer code.
When the required digit is selected, press the OK key to confirm
and go to step 5.