Herunterladen Inhalt Inhalt Diese Seite drucken

ECG VP 908 Bedienungsanleitung Seite 37

Bodenstaubsauger
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 27
DUST BAG FULL INDICATOR
The vacuum cleaner is equipped with an indicator that turns red if the dust bag is full, the filter is clogged
or the suction paths are otherwise blocked. To prevent overheating and possible damage to the vacuum
cleaner, check the following:
all the connections between hose, telescopic tube and the floor brush
Suction opening for connecting the hose
Brush throughput
HEPA filter and motor filter
Dust bag
CHANGING DUST BAG
1.
Before performing maintenance, always pull the plug of the power cable from the AC outlet.
2. Pull out the hose from the suction opening and press the button on the bottom part of the handle and
lift the cover to open the vacuum cleaner.
3.
Remove the dust bag by pressing the holder (Fig. 8).
Fig. 8
4. Hold the new dust bag by the edges and replace the original one, secure it by pressing the holder.
5.
Close the vacuum cover by pushing the cover back until you hear a click.
REPLACEMENT OF THE INPUT AND OUTPUT FILTERS
To ensure proper functioning of the vacuum cleaner, it is very important the replace both filters
regularly.
It is recommended to change the input and output filters at the latest at fifth change of the dust bag or earlier
if you notice strong accumulation of dirt.
Replacement output and input filters have to be always new and original.
1.
Input filter (motor protection filter) is located in the dust bag space (Fig. 9). Remove carefully the old filter,
place new one, and make sure it holds in place correctly and firmly.