f Flash Firing Restrictions due to Temperature Increase
When continuous flash or modeling flash is repeatedly fired in short
intervals, the temperature of the flash heads, batteries, and the area
near the battery compartment may increase.
When you perform firing repeatedly, the firing interval increases in
steps within the range of up to approx. 20 sec. to avoid degrading
or damaging the flash heads due to overheating. When you
perform firing repeatedly even more in this state, flash firing is
restricted automatically.
Furthermore, when flash firing is restricted, a warning icon is
displayed to indicate the increase in temperature, and the firing
interval (with which the flash photography can be performed) will
be automatically set to approx. 8 sec. (level 1) or approx. 20 sec.
(level 2).
Temperature Increase Warning
As the internal temperature of the flash unit increases, the warning is
displayed in two levels. When you perform continuous firing repeatedly
even more in the state in level 1, the state changes to level 2.
Display
Icon
LCD panel illumination
Number of Continuous Flashes and Rest Time
The following table shows the number of continuous flashes until the
warning (level 1) is displayed, and the necessary rest time (guideline)
until normal flash photography can be performed.
Function
Continuous full output
flash (p.7)
Modeling flash
28
Level 1
(Firing interval:
Approx. 8 sec.)
e
Red (lit)
Number of Continuous
Flashes to Reach Level 1
Warning (Guideline)
48 times or more
Level 2
(Firing interval:
Approx. 20 sec.)
f
Red (blinking)
Necessary Interval
Time (Guideline)
25 min. or longer