Installation

Flash through the supply pipes.
Install box depending on the building application.
Watch the depth of installation (see sticker on the
installation box).
Large differences in pressure between the hot and
cold water supply should be balanced.
The hot water connection must always be LHS and the
cold water connection RHS. The mixed water outlets
in the top and bottom of the housing can be used
singly or jointly as required. For single connection
the outlet not in use must be properly sealed with
the screw plug.
Stop valve(s) must be provided to control the
fl ow of mixed water from the outlet(s).
After completion the whole installation must be
fl ashed. For this action the cold water and mixed
water pipes are connected in the fl ushing unit. The
hot water supply pipe is lfushed on the fl ushing unit,
the cold water and mixed water supply pipes on the
outlets. Afterwards check the pipes and connections
for leakage.
Important!
In the event of frost hazard and draining the pipes,
the fl ushing unit must be removed and the thermo-
static mixer body drained.
Final installation
Finish sets ½" and ¾"
Mondaro
Starck
Arco
Allegroh
Steel
Azzur
Terrano
Carlton
Uno
Mondial / Metropol /
Metris / Talis Elegance /
Talis Sportive
18375XXX
10375XXX
11375XXX
36375XXX
35375800
34375XXX
37370XXX/37375XXX
17375XXX/17377XXX
13375XXX
15375XXX
English
Technical data
Minimum fl ow pressure with
downstream resistance
Max. operating pressure
Recommended operating pressure
Test pressure
Max. hot water temperature
Temperature scale adjustible
Safety check
Hot water connection
Cold water connection
Nominal capacity for ½" and
¾" by 3 bar
Minimum fl ow rate
Test certifi cate
The water temperature at the hot water inlet should
be at least 2° C higher then the desired hot water
temperature.
The Hansgrohe ¾" thermostatic mixer can be used
in conjunction with hydraulic or thermostatically
controlled combination boilers providing there is a
minimum of 1,5 bar pressure and the combinaton
boiler prepare enough water for the downstream
consumption.
0,5 bar
10,0 bar
1,0 - 5,0 bar
16,0 bar
80° C
20° - 80° C
38° C
LH
RH
50 l/min
5 l/min
WRAS
MCA
9