Check the power source for the trolley, ensure that the fan is not blocked and that the sensor behind the air circuit is clear and clean.
If the «spanner + hand» pictogram appears, the safety thermostat has been triggered, the trolley is in fault. Contact your installer.
- The following pictograms appear :
Press the screen once
An adjustment problem is detected. Check that the temperature sensor behind the air circuit is clean and clear. Confirm the error message.
If the «spanner + hand» pictogram appears, the trolley is in fault. Contact your installer.
- Humidification is not sufficient :
The spray nozzle is clogged :
* Dismount the air circuit manually by pulling it upwards then towards you once it has shifted
* Remove the nozzle manually from the tube (1) via the large yellow nut (5).
* Check that the screen (2) and the seals (6) are in good condition.
* Dismount the jet orifice (3) of the head of the nozzle (4) using a flat-head screwdriver
* Soak the orifice (3) + nozzle (4) unit in a descaling solution or vinegar, let stand for 8h.
* Check that the hole of the orifice (3) is not clogged.
* Remount the unit.
For any other breakdown, contact your installer.
y On cold trolleys that are operating :
- The following pictogram appears :