Assembly
Attention! The fitting must be installed, flushed and
tested after the valid norms!!
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer in
position on the sink.
3. Slip the plastic washer, the slide washer, the metall
washer and collar over the hoses and threaded
base and tighten the collar nut by hand. If there
is not enough space, please use only the slide
washer and the metal washer without the plastic
washer.
4. Tighten screws.
5. Connect the supply pipes to the isolation valves;
cold right - hot left.
6. Connect the hose with hose nut, taper sleeve,
disc and washer.
7. Mount the hose weight as required - be careful
by the max. drawn out, otherwise the hose could
be damaged.
After the assembly!
8. Dismount the handspray and the filter.
9. Flush through the hose.
10. Cleaning the filter.
11. Mount the filter and the handspray
12. To connection down, hand-screwed (1 Nm).
13 Check the smooth run and the function of the
hose
The hot and cold supplies must be of equal
pressures.

Operation

The mixer is activated by lifting the lever handle.
Turning to the left = warmer water,
turning to the right = cooler water.
The handspray can be drawn approx. 50 cm out
of the arm lining. The spray mode is changed to
showerspray by pressing the front button
top of the sprayhead. By pressing the rear button
or switching off the water, the spray mode changes
to aerated spray
If the waterflow drops, clean the filter located between
hose and handspray.

English
Technical Data
Operating pressure:
Recommended operating pressure: 0,15 - 0,5 MPa
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temperature: 65° C
Rate of flow by 0,3 MPa aerated spray: 9 l/min
Rate of flow by 0,3 MPa shower spray: 10 l/min
Test certificate:
Anti-pollution function
Hansgrohe single lever mixers can be used together
with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0,15 MPa.
To adjust the hot water limiter on single lever mixers,
please see page 12.
No adjustment is necessary when using a continuous
flow water heater.
Maintenance non return valve
The non return valves must be checked regularly
according to DIN EN 1717 in accordance with
national or regional regulations (at least once a
year).
Spare parts (see page 3)
1
handle
1.1 screw cover
2
flange
3
nut
4
cartridge cpl.
5
locking screw for handle
6
hose 1,25 m
7
handspray assy
8
aerator cpl.
aerator gold plated
on the
9
fixing set
10 non return valve DW 15 (2)
11 connection hose 900 mm
12 lever collar set
XXX = Colors
000 chrome plated
090 chrome plated/gold plated
800 stainless steel optic
max. 1 MPa
1,6 MPa
max. 80° C
WRAS
14890XXX
96338000
96391XXX
94194000
92730000
96059000
95048000
14893XXX
13955000
94980990
95049000
94074000
98758000
97599000