Herunterladen Inhalt Inhalt Diese Seite drucken

RIDGID micro CM-100 Bedienungsanleitung Seite 7

Digital-messzange
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 59
Input Limits
Function
Voltage V DC/AC
Current A DC/AC
Frequency, Duty Cycle
Accuracy is given at 18°C to 28°C (65°F to 83°F), less than 70% RH
DC Current
Range
40 A
400 A
1000 A
AC Current
Range
40 A
400 A
1000 A
DC Voltage (Autoranging)
Range
400 mV
4 V
40 V
400 V
600 V
Input Impedance ...........................10.0 MΩ
AC Voltage (Autoranging)
Range
400 mV
4 V
40 V
400 V
600 V
Input Impedance...........................10.0 MΩ
Resistance (Autoranging)
Range
400 Ω
4 kΩ
40 kΩ
400 kΩ
4 MΩ
40 MΩ
micro CM-100 Digital Clamp Meter
Resolution
0.01 A
0.1 A
1 A
Resolution
0.01 A
0.1 A
1 A
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.1 Ω
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
Maximum Input
600 V DC/AC
1000 A DC/AC
600 V DC/AC
Accuracy
±2.8% of Reading ± 10 Digits
±2.8% of Reading ± 8 Digits
±3.0% of Reading ± 8 Digits
Accuracy
±2.8% of Reading ± 10 Digits
±2.8% of Reading ± 8 Digits
±3.0% of Reading ± 8 Digits
Accuracy
±0.8% of Reading ± 2 Digits
±1.5% of Reading ± 2 Digits
±2.0% of Reading ± 2 Digits
Accuracy
±1.0% of Reading ± 10 Digits
±1.5% of Reading ± 8 Digits
±2.0% of Reading ± 8 Digits
Accuracy
±1.0% of Reading ± 4 Digits
±1.5% of Reading ± 2 Digits
±2.5% of Reading ± 5 Digits
±3.5% of Reading ± 10 Digits
5

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis