product must be placed in a frost-free room to prevent the pum-
ped liquid from freezing.
Make sure that all external pipework is adequately insulated.The
discharge pipe must be made of rigid material, such as copper, or
of rigid PVC with solvent-welded joints.To prevent the transmis-
sion of vibrations to buildings, make sure that the pipework is tho-
roughly fixed and that fittings cannot move and are not in contact
with building parts.
Extension pipes between the toilet and the system must not be
longer than 150 mm due to the increased risk of clogging.

4. ELECTRICAL CONNECTION

Make sure that the product is suitable for the supply voltage and
frequency available at the installation site.The electrical connec-
tion must be carried out in accordance with local regulations.
The product must be earthed.
The installation must include an earth leakage circuit breaker for
protection against earth fault currents. Thisensures protection
when using a Schuko plug or another plug with earth pin.The pro-
duct must be connected to a mains switch with a minimum contact
gap of 3 mm in all poles.In case of overtemperature, a thermal
switch cuts out the motor and cuts it in automatically when it has
cooled sufficiently.

5. ACCESSORIES

1- An alarm device for acoustic alarm in case of malfunction or high level
in the tank is available as an accessory (noise level 75 dB(A)). Product
number: 60166477.
2- A kit containing: a hose (length 500mm) with adapter, available as an
accessory. Product code 60168126
1
6. MAINTENANCE
The system does not require any particular maintenance, but we recom-
mend checking the operation and couplings of the pipes at least once a
year.

6.1 Adjustment of run time

The default setting ensures proper operation in most pipework. If the pi-
pework is particularly long or short, it may be necessary to adjust the run
time.
6.2 Service instructions
Thanks to the product design, service is easy in case of malfunction or
blocked pump.
Digits in the following sections refer to the pictures in the appendix
bleshooting".
Before carrying out any service work, remove the fuse, pull out
the plug, or switch off the power supply. Make sure that the power
supply cannot be accidentally switched on.All rotating parts must
have stopped moving.The product must only be serviced by trai-
ned service personnel.
Impeller/grinder stuck
1. Disconnect the power supply
2. Remove the motor cover cap.
3. Insert a screwdriver (min. 110 mm) through the plug hole and into the
2
GB
ENGLISH
"Trou-
11