Installation; Special Software Requirements; Firmware Version; Installation Notes - Mettler Toledo IND9D57/Dyn-570 Installationshandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2.

Installation

2.1.

Special Software Requirements

2.1.1.

Firmware Version

The Dyn-570 application was created using TaskExpert™. To run a TaskExpert application, the
IND570 must have version 2.00.0036 firmware or higher installed.
2.2.

Installation Notes

If a complete IND570dyn terminal is ordered, all files required to run the Dyn application will be
loaded during production and this chapter can be skipped. If the Dyn-570 application is ordered as
a separate kit, the Dyn-570 application files must be loaded to the terminal before the application
can run.
The required files are available for download at www.mt.com/IND570.
2.2.1.

Installation Method

The following procedure outlines installation of the Dyn-570 application files.
2.2.1.1.

Loading via USB

1. Make certain that the USB port has been enabled for both read and write functions in setup at
2. Transfer the files downloaded from
3. Insert the USB flash drive into the IND570 USB port.
4. Enter setup and navigate to Maintenance > Run > Restore from USB.
5. Select TaskExpert from the Restore selection box.
6. Press the START softkey
7. When all files have been loaded, a message will be shown indicating a successful restore.
8. Exit setup and remove the USB flash drive.
9. The application is now ready for programming.
30416342
|
02
|
12/2018
Communication > Access/Security > USB.
folder with the following path. The folders must be named exactly as shown:
(USB drive) \ IND570 \ (SN of terminal) \ TaskExpert
METTLER TOLEDO IND9D57/Dyn-570 Dynamic Weighing System Installation Manual
www.mt.com/IND570
to begin the loading process.
to a USB flash drive in a TaskExpert
2-1