Herunterladen Inhalt Inhalt Diese Seite drucken

WABCO ABS/ EBS Code Reader Handbuch Seite 18

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 49
Fault codes and their meaning
SPN
EN
9
10
11
211
212
213
214
215
216
217
218
251
253
254
VCSII
FMI
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
TEBS-D
SPN
1
2
3
18
AFFECTED COMPONENT
Solenoid valve C
Solenoid valve B
Internal outlet solenoid valve
GenericIO D1
GenericIO D2
GenericIO logic
GenericIO D4
GenericIO D5
GenericIO A1
GenericIO logic
GenericIO logic
Power supply
Memory calibration EEPROM
Control unit
FAULT DESCRIPTION
Value too high (short circuit to supply voltage)
Value too low (undervoltage / short circuit to ground / air gap)
Incorrect value (cable break)
Overvoltage or short circuit to supply voltage
Undervoltage or short circuit to ground
Current too low (cable break)
Current too high (interturn short circuit)
Mechanical fault (pole wheel defective)
Unusual frequency (impermissible wheel slip)
Unusual signal form (no wheel speed)
Unusual signal changes (speed jump)
Fault cannot be identified
Internal electronic fault
Characteristic curve error (pole wheel eccentric)
Special fault / see fault note
Reserved (ECU defective)
AFFECTED COMPONENT
Rotational speed sensor c
Rotational speed sensor d
Rotational speed sensor e