FAILURE
Pump does not work and the pump indicator does not turn on
Flame goes off while the pump is still working
Combustion chamber makes noise
There is unburned oil left on the vaporising pan or too much diesel oil during switching on
CAUSE
No
1
No power supply
2
Water or residues in the tank.
4
The engine and pump do not turn on.
5
through return pipe
6
Pump thermostat did not reach desired tempe-
rature.
7
9
Insufficient air supply for heating
10
Draught problems
11
12

TECHNICAL SPECIFICATIONS:

Minimum heating performance
Maximum heating performance
Minimum oil consumption
Maximum oil consumption
Power supply
Power intake
Flue diameter
Width
Height
Length
Weight
16 |
REMEDY
Check if the device is plugged in correctly and check the fuse.
Clean the tank and filter
Fuel is too thick or too cold. Dilute with diesel oil.
Check the pump thermostat and replace, if necessary.
Check the engine in order to determine if the pump is not dirty inside.
Clean the oil pipe and replace, if necessary.
Wait until the burner cools down and relight.
Replace the thermostat.
Clean
Clean air inlets in the combustion chamber.
Clean, if necessary
Install the draught stabiliser and set at 2 mm W.C. (16 Pa).
Check all joints.
Minimize the number of bends
HP105
kW
15
kW
22
kg/h
1,25
kg/h
1,85
V/Hz
230/50
A
0,6
mm
150
cm
54
cm
114
cm
78
kg
70
CAUSE
6 - 3 - 7
2 - 5 - 9 - 10 - 12
10 - 11 - 12
9 - 10 - 11 - 12
9 - 11 - 12