Figure 2: Diagram of HP 105 universal
oil heater
T40
Bimetallic sensor
of burner's temperature
OVFL
PUMP
Pump (8W / 230VDC]
KB
keyboard
LED2
Overfow tank indicator
LED3
Pump control
LED4
Heater turn on/off indi-
cator
Control panel
Figure 3: Control panel
Terms:
burner thermostat
pump
230V, 50 Hz
control panel
HITON - heat your home, not the planet
7. Installation
When installing the heater, all local
regulations are to be complied with,
including regulations referring to
national norms.
1.
made of concrete.
2. Level the device in order to check if
the heater is levelled correctly, place
the vaporising pan in the lower part
of the combustion chamber and pour
a small amount (approximately 250ml)
of diesel oil onto it. The oil should stay
exactly in the middle of the pan.
3. Install current stabilizer (valve) on
the combustion chamber's outlet pipe
in order to maintain constant draught
inside the pipe during the operation.
4. Install at least six meters long,
smooth and temperature resistant
order to provide optimum draught.
5. Check tightness of all joints, if
necessary use the insulation tape.
6. Make sure that the vaporising pan
is placed centrally in the combustion
chamber.
7. Place the upper ring inside the
facing upwards and install the hot air
pipe.
8. Check the power (220-240V/50Hz)
and connect the heater to the power
outlet. The pump shouldn't become
active because the burner has not
been switched on and the heat has not
been produced yet.
9. The heater should be placed away
from combustible materials
Ventilation fans working in the
same room or area as the heater
may cause disruptions.
Fitting the flue
To ensure the right combustion
in necessary. The following
recommendations should be adhered
elements.
insulated (double skinned).
The tube should be in free air
rooftop).
should be in vertical position,
horizontal positioning should be
However, if it is necessary to bend
places when it runs through a wall
or a window), the maximum angle is
increased to 7m.
nominal heat.
The device cannot be connected to the
joint combustion outlet system.
CAUTION!
When installing the combustion
outlet system it is recommended
position. In order to guarantee free
movement of gases, the angle of
outlet must be above the rooftop.
Flues running through the
ceiling, walls or the roof, must be
insulated in order to prevent fire.
It is recommended to use double
general public and on the outside of
the building in order to guarantee
good draught and prevent
condensation. No materials should
be placed close to the heater,
even incombustible ones. Free air
movement should be provided to
assure proper combustion process.
Figure 4: Fitting the flue
ENG
| 13