8. Functionning
Control panel
The control panel of HP 105 universal
oil heater is equipped with two
buttons enabling the user to control
the operation of the heater and two
diodes signalling the operating modes
of the device.
Figure 5: ..
Terms:
heater output control
on switch
off switch
4
control
pump control
5
heater readiness for use
LED diodes
The device operates in the following
modes:
S
Device ready for use
TOP
H
Preliminary operating
EATING UP
phase
I
The device is working
N OPERATION
normally
S
The device is shutting
HUTTING OFF
off
T
-
Contingency switching
ANK OVER
off
FLOW
The heat is produced during gas
combustion when oil is heated up to
a high temperature. When connecting
the heater to power network, the
device is in stand-by mode (Stop).
Heat is not produced and pump is not
working. Pressing the Start button
triggers the green diode to turn on
and the heater goes into the heating
up mode. Once the burner is heated
up to 40°C the joints of thermostat
placed next to combustion chamber
clutch activating the oil inlet pipe
14 |
fan; these are signalled by the yellow
diode on the control panel. At the
beginning smaller amount of oil is
required for at least 30 minutes, when
the burner has not been heated up,
and the device should work on its
minimum gear. During this time, the
pump feeds the combustion chamber
with approximately 1.25 kg/h (HP 115)
or 1.85 kg/h (HP 125) of oil. After 30
minutes, we may shift to maximum
gear by turning the potentiometer
knob), during which time the chamber
is supplied with approximately 1.85
kg/h of oil.
The heater is switched off by pressing
Stop button on the control panel.
The pump is switched off (yellow and
green diodes on the control panel go
off).
The heater may switch off
the vaporising pan.
by a mechanic sensor located
Opening of joints signals that the
the pump is switched off, the pump
indicator goes off, and the red diode
then Start button should be pressed,
diode to go off. The heater may be
switched on again.
9. How to operate the heater
CAUTION!
Oil must not be poured into the
burner if the chamber or the pan
is still hot!!! Always wait until the
burner has cooled down. Non-
compliance with the above warning
may cause explosion of oil vapours
and burns!!!
How to operate the device
Once engaged, the heater switches to
desired modes depending on settings
chosen by the user and information
transmitted by sensors connected to
the control panel.
If necessary, water may be poured
from the tank and replaced with used
oil.
Plug into the power socket
(230V/50Hz).
Pull the upper part of the cover aside
and take the burner lid off, take the
cylinder and the ring out (if necessary,
clean thoroughly the vaporising pan
and its base, the burner, cylinder
and ring). Check if the vaporising
pan is cool and clean, and then pour
approximately 250 ml of heating or
diesel oil onto it.
Light oil using a piece of scrunched up
paper that needs to be put on fire and
thrown onto the vaporising pan.
Install ring and cylinder, put the
burner lid back on, close the upper
part of burner's casing.
Press Start button on the control
panel (green diode turns on)
After approx. 10-15 minutes,
depending on the temperature in
the room, the fuel pump will start
and the yellow pump diode will turn
on at the same time. The heater
starts working on the lowest gear
with lower performance and can
continue operating in this mode on
a continuous basis:
15 kW; 1.25 kg/h
The increased heat otput can be
activated by turning the potentiometer
knob on the control panel:
22kW; 1.85 kg/h
Each time Stop button is pressed
followed by pressing the Start
button during operation will result in
switching into the Heating up mode of
the burner.
Shutting off
Press Stop on the control panel
(yellow diode goes off), pump stops
feeding fuel onto the vaporising pan.
The burner switches off
automatically. Please remember
that after switching off the device,
the cast-iron pan remains hotter
for longer (depending on the
temperature in the room) and the
heater cannot be re-engaged until it
cools down completely.