BA24
20
21
22
23
24
25
JP3
26
27
RESERVE
28
29
30
JP5
31
STOP input (N.C.).
STOP
If not used, jumper with terminal n° 29.
Opening limit switch input - motor 1 (N.C.).
FCAM1
If not used, disable during programming.
Closing limit switch input - motor 1 (N.C.).
FCCM1
If not used, disable during programming.
Opening limit switch input - motor 2 (N.C.).
FCAM2
If not used, disable during programming.
Closing limit switch input - motor 2 (N.C.).
FCCM2
If not used, disable during programming.
PHOTOCELL 2 input (N.C.).
If not used, disable during programming.
Operation:
Input active during both opening and closing.
If intercepted, it immediately stops the motion and holds it stopped until the photocell
PHOTO 2
is freed. Upon release, motion always restarts in opening.
If intercepted when the gate is closed, following a Start command, it does not allow
opening the gate and it will be signalled with 5 fast flashes, then the warning light
turns on to indicate that the gate is not in stand-by. Upon release, the gate will start
opening without further commands.
If intercepted during pause, it reloads the pause time.
PHOTOCELL 1 input (N.C.).
If not used, disable during programming.
Operation:
PHOTO 1
Input active only during closing.
It stops and inverts the motion, opening the gate completely.
If the gate is closed, it does not affect its functioning.
If intercepted during pause, it reloads the pause time.
Multifunctional input.
SAFETY DEVICES input (see menu C9)
If not used, disable durino programming.
Operation:
IInput active during both opening and closing.
It stops and inverts the motion for 2 sec. The gate will remain locked until the next
EDGE
Start pulse, which will restart it in the obstacle freeing direction.
When active in stand-by, after the start/pedestrian command the door does not move
and 3 long flashes (2 sec.) will signal the anomaly.
If active in pause, the door does not close automatically (if expected) and
3 long flashes (2 sec.) will signal the anomaly.
THE EDGE ACTIVATION IS SIGNALLED BY THE WRITING "SAF" ON THE LCD.
COM
Common inputs-outputs
GND
ANTENNA BRAID input
ANT
ANTENNA SIGNAL input
External clock:
SEE PROGRAMMING C16-C17-C18