40
UK
EXTERNAL CLOCK
C16
CLOSING ALLOWED
(set automatic closing)
EXTERNAL CLOCK
C17
CLOSING NOT ALLOWED
(set automatic closing)
EXTERNAL CLOCK
C18
AUTOMATIC OPENING AND
CLOSING COMMAND
C20
PHOTOCELL 1 TEST
Enables the RESERVE input for the connection of an external clock.
Operation:
When the clock closes the contact on the RESERVE input, following a
START command the door will open but not close automatically. When
the contact on the RESERVE input is opened, the door will
Y
automatically close after the pause time.
When the door is open, the closing command can be given with "start"
if the menu is STEP-BY-STEP or STEB-BY-STEP with STOP.
WARNING: remember to preset the automatic closing, the activation of
this menu automatically defuse C17-C18.
N
Disables the RESERVE input
Enables the RESERVE input for the connection of an external clock.
Operation:
When the clock closes the contact on the RESERVE input, following a
START command the door will open but not close automatically. When
the contact on the RESERVE input is opened, the door will
Y
automatically close after the pause time.
It is not possible to activate the closing with the "start" command.
WARNING: remember to preset the automatic closing,the activation of
this menu automatically defuse C16-C18.
N
Disables the RESERVE input
Enables the RESERVE input for the connection of an external clock.
Operation:
When the clock closes the contact on the RESERVE input, an opening
command will automatically be activated without needing to give a
Y
START command. When the contact on the RESERVE input is opened,
the door will automatically close after the pause time.
WARNING: remember to preset the automatic closing, the activation of
this menu automatically defuse C16-C17.
N
Disables the RESERVE input
Enables the Photocell 1 test.
The photocell 1 transmitter must be connected to the clamps 14 and 17.
Operation:
Y
When the "Start" or the "Pedestrian" command is given, the power to
safety devices is cut off for 0,5 and then restored: if the photocell 1 input
opens and immediately returns NC the motors start, otherwise a fault will
be signalled by 4 blinks (1 sec.) of the flashing light.
N
Disables photocell 1 test.