Herunterladen Inhalt Inhalt Diese Seite drucken

Important Remarks; Declaration Of Conformity; Technical Specifications - V2 Easy2 Bedienungsanleitung

Analoge steuerung für rollläden und schwingtore
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 33

IMPORTANT REMARKS

For any installation problem please contact our Customer Service
at the number +39-0172.812411 operating Monday to Friday
from 8:30 to 12:30 and from 14:00 to 18:00.
V2 has the right to modify the product without previous
notice; it also declines any responsibility to damage or
injury to people or things caused by improper use or
wrong installation.
Please read this instruction manual very carefully
before installing and programming your control unit.
• This instruction manual is only for qualified technicians,
who specialize in installations and automations.
• The contents of this instruction manual do not concern the
end user.
• Every programming and/or every maintenance service
should be done only by qualified technicians.
AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE
WITH THE EUROPEAN REGULATIONS IN FORCE:
EN 60204-1 (Machinery safety. electrical equipment of
machines, part 1: general rules)
EN 12445
(Safe use of automated locking devices,
test methods)
EN 12453
(Safe use of automated locking devices,
requirements)
• The installer must provide for a device (es. magnetotermical
switch) ensuring the omnipolar sectioning of the equipment
from the power supply.
The standards require a separation of the contacts
of at least 3 mm in each pole (EN 60335-1).
• After making connections on the terminal board, use one
hose clamp to fix dangerous voltage wires near the terminal
board and another hose clamp to fix safety low voltage wires
used for accessories connection; this way, in case of
accidental detachment of a conducting wire, dangerous
voltage parts will not come into contact with safety low
voltage ones.
• The plastic case has an IP55 insulation; to connect flexible
or rigid pipes, use pipefittings having the same insulation
level.
• Installation requires mechanical and electrical skills,
therefore it shall be carried out by qualified personnel only,
who can issue the Compliance Certificate concerning the
whole installation (EEC Machine Directive 89/392, Annex IIA).
• The automated vehicular gates shall comply with the
following rules: EN 12453, EN 12445, EN 12978 as well
as any local rule in force.
• Also the automation upstream electric system shall comply
with the laws and rules in force and be carried out
workmanlike.
• The door thrust force adjustment shall be measured
by means of a proper tool and adjusted according to
the max. limits, which EN 12453 allows.
• Connect the earthing lead of the motors to the electricity
grid earth system.
• Observe all necessary precautions (e.g. anti-static bracelet)
for handling parts sensitive to electrostatic discharges.

DECLARATION OF CONFORMITY

V2 S.p.A. hereby declare that EASY2 products conform to the
essential requirements established in the following directives:
- 2004/108/CEE (EMC Directive in accordance with standards
EN 61000-6-2, EN 61000-6-3 + EN 50336)
- 2006/95/CEE (Low Voltage Directive in accordance with
standards EN 60335-1 + EN 60335-2-95 + EN 60335-2-97)
- 99/05/CEE (Radio Directive in accordance with standard
EN 301 489-3)
Racconigi, lì 28/01/2010
V2 S.p.A. legal representative.
Cosimo De Falco
DESCRIPTION OF THE CONTROL UNIT
The EASY2 control unit is an innovative V2 product guaranteeing
safety and reliability for roller shutters and counterweight
balanced doors.
The EASY2 design has been aimed at creating a product which
adapts to suit all needs, thus obtaining an extremely versatile
control unit satisfying all the necessary requirements for a
functional and efficient installation.
• 230V - 50Hz or 120V - 60Hz power supplies, depending on
the model, for 1 x 700 W max. single phase motor.
• 2 inputs for key selector switch or button activation.
• Input for safety photocell.
• Input for safety edge, capable of handling standard edges
with switch normally closed, optical edges and conductive
rubber edges with nominal resistance of 8.2 kOhms.
• Output for blinking light, 120/230V - 40W
• Pre-opening safety device testing.
• Dip-switch programmable operational logic.
• Adjustment of the operation time by means of a trimmer.
• Quick plug-in connector for inserting a Mr1 series receiver.
• LED monitoring of inputs.
• Courtesy light output.
• IP55 casing.
TECHNICAL
SPECIFICATIONS
Power supply
Max motor load
Max accessories load 24V
Working temperature
Protection fuse
Dimensions
Weight
Protection
7
230V models
120V models
230V / 50Hz
120V / 60Hz
700W
700W
3W
3W
-20 ÷ +60 °C
-20 ÷ +60 °C
F1 = 5A delayed F1 = 8A delayed
170 x 185 x 70 mm
800 g
IP55

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis