PROBLEM
1.With the key on «START»
cause the starter motor
does not run
2. With the key on «START» the
Starter motor runs but the engine
does not start
3. The engine stops
LIKELY CAUSE
Electric part blocked due to:
– flat battery
– fuse blown
– bad earthling to the engine or the frame
– earth connections of the micro switches
–faulty fuel supply
–faulty ignition
Electric part blocked due to:
–earth connections of the micros witches
Turn the key to «STOP» and look for the of
the problem:
– recharge battery (☛6.2.3)
– replace fuse (10A) (☛6.3.4)
– check connections of black earth leads
– check connections
–check the level in the tank (☛5.3.3)
–check the wiring of the fuel open command
–check fuel filter
–check that spark plug caps are firmly fitted
–check that the electrodes are clean and have
the correct gap
Turn the key to pos. «OFF» and look for the
cause of the problem:
–check connections
-97-
SOLUTION