Herunterladen Inhalt Inhalt Diese Seite drucken

Appendix - PeakTech 1885 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für 1885:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

APPENDIX A
COMMMAND SET
Remarks in using the Remote Programming Mode The USB/485 interface is always ready for
connection to PC for remote programming operation .
{ }- command data, [ ] - return data, [OK] = "OK", [CR] = 0dh
???? = 30h, 30h, 30h, 30h - 39h, 39h, 39h, 39h (4 bytes data)
??? = 30h, 30h, 30h - 39h, 39h, 39h (3 bytes data)
?? = 30h, 30h – 39h, 39h (2 bytes data)
<address> 30h, 30h - 3fh, 3fh (2 bytes data).
Bold – Input Command
Italic – Return Data from Power Supply
Input Command:
SESS <address> <CR>
Return Data from Power Supply:
[OK] [CR]
Input Command:
ENDS <address> <CR>
Return Data from Power Supply:
[OK] [CR]
Input Command:
CCOM <address> <RS> {000-256} <CR>
Return Data from Power Supply:
[OK] [CR]
Input Command:
GCOM <address> <CR>
Return Data from Power Supply:
[RS] RS485 Address [??] [CR]
[OK] [CR]
Input Command:
GMAX <address> <CR>
Return Data from Power Supply:
Voltage [???] Current [???] [CR]
[OK] [CR]
Input Command:
GOVP <address> <CR>
Return Data from Power Supply:
Voltage [???] [CR]
[OK] [CR]
Input Command:
GETD <address> <CR>
PS = Power Supply
Command Code & Return Data
28
Description
Disable front panel
keypad and make PS to
Remote Mode
Enable front panel
keypad and make PS to
exit Remote Mode
Change RS485
<RS> = 0 -> RS-232
<RS> = 1 -> RS-485
Get the RS-485
address
Get maximum voltage
and current of PS
Get Upper Voltage
Limit of PS
Get Voltage & Current
reading from PS

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

1890

Inhaltsverzeichnis