Voltage [????] Current [????] [0] [CR]
[OK] [CR]
Voltage [????] Current [????] [1] [CR]
[OK] [CR]
Input Command:
GETS <address> <CR>
Return Data from Power Supply:
Voltage [???] Current [???] [CR]
[OK] [CR]
Input Command:
GETM <address> <CR>
Return Data from Power Supply:
Memory 1 Voltage [???] Current [???] [CR]
Memory 2 Voltage [???] Current [???] [CR]
.
.
.
.
.
.
.
.
.
Memory 9 Voltage [???] Current [???] [CR]
[OK] [CR]
Input Command:
GETM <address> location {1-9} <CR>
Return Data from Power Supply:
Voltage [???] Current [???] [CR]
[OK] [CR]
Input Command:
GETP <address> <CR>
Return Data from Power Supply:
Program 00 Voltage [???] Current [???] Minute [??] Second [??] [CR]
Program 01 Voltage [???] Current [???] Minute [??] Second [??] [CR]
.
.
.
.
.
.
.
.
.
Program 19 Voltage [???] Current [???] Minute [??] Second [??] [CR]
[OK] [CR]
Input Command:
GETP <address> program {00-19} <CR>
Return Data from Power Supply:
Voltage [???] Current [???] Minute [??] Second [??] [CR]
[OK] [CR]
Input Command:
GPAL <address> [CR]
Return Data from Power Supply:
Reading voltage [####] V [ON]
Reading current [####] A [ON]
Reading watt [####] W [ON]
Command Code & Return Data
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
14
Description
PS in CV mode
PS in CC mode
Get Voltage & Current
Set Value from PS
Get All Preset Memory
Values from PS
Get Memory from
Specific Preset of PS
Get all the Timed
Program Memory of PS
Get Timed Program
Memory from Specific
Program of PS
Get LCD Display
Information