Herunterladen Inhalt Inhalt Diese Seite drucken

Initial Commissioning; Information In The Case Of Any Faults; Spare And Wearing Parts - Bosch 0 986 618 001 Produktbeschreibung

Prüfadapter für generatorregler mit lin- / bss-schnittstelle
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
en
12 | 0 986 618 001 | Initial commissioning
4.

Initial commissioning

4.1
Preparation
Using the enclosed self-adhesive hook & loop straps, it
is possible to fasten the adapter to a exposed, readily
accessible location on the alternator test bench.
i
Ensure that the location on the alternator test
bench is clean and grease-free. If necessary, clean
it beforehand with a commercially available, grease-
dissolving cleaning agent.
Fig. 3:
Fastening the hook & loop straps
1. Remove the protective backing from two hook &
loop straps and place them on the back of the test
adapter (fig. 3, items 1 and 2).
2. Press the other two hook & loop straps against the
hook & loop straps attached to the adapter.
3. Remove the protective backing from the two hook &
loop straps and fasten the test adapter to an expo-
sed, readily accessible location on the alternator
test bench. Apply pressure briefly to improve the
holding force.
4.2
Connecting the test adapter
Important information about connecting and using the
test adapter can be found in the separate ESI[tronic]
component repair manual for compact alternators in
the section "Incoming and outgoing test". It is essential
that these instructions be read carefully and observed
before using the test adapter.
|
1 689 989 265
2015-08-25
5.
Service
5.1
Cleaning
Wipe off the housing of the adapter with a clean cloth,
or blow it off with compressed air.
!
Do not use any alcohol-containing cleansers that can
damage the housing.
5.2

Information in the case of any faults

FAULT
Protection switch in test
adapter has tripped.
No function test possible
6.

Spare and wearing parts

Designation
Adapter
B+/B– connection cable; 1.5 m <)
Alternator regulator connection cable; 1.5 m
<)
Test adapter cable 0.3 m <)
Test adapter cable 0.3 m <)
Test adapter cable 0.3 m <)
Test adapter cable 0.3 m <)
<) Wearing part
NOTE
1. Polarity of voltage supply in-
correct.
Remedy:
R Connect terminals of the
B+ / B– connection cables
correctly.
R Actuate protection switches
(fig. 1, items 5, 7).
2. Short circuit from uninsula-
ted measurement cable con-
nection.
Remedy:
R Eliminate short circuit.
R Actuate protection switches
(fig. 1, items 5, 7).
R Use measurement cables
with a safety connector.
See information in the sepa-
rate ESI[tronic] component
repair manual for compact
alternators in the section "In-
coming and outgoing test".
Item number
1 681 032 117
1 684 463 958
1 684 463 959
1 684 460 293
1 684 460 295
1 684 460 294
1 684 460 296
Robert Bosch GmbH

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading