6 – English
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected
by absorption and reflection from structures, objects and people.
a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless)
telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV
broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic
environment due to fixed RF transmitters, an electromagnetic site survey should be
considered. If the measured field strength in the location in which the EUT is used exceeds
the applicable RF compliance level above, the EUT should be observed to verify normal
operation. If abnormal performance is observed, additional measures may be necessary, such
as reorienting or relocating the EUT.
b
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than [3] V/m.
Table 3: Recommended separation distances between portable and
mobile RF communication equipment and the EUT
The EUT is intended for use in the electromagnetic environment in which radiated RF disturbances
are controlled. The customer or the user of the EUT can help prevent electromagnetic interference
by maintaining a minimum distance between portable and mobile RF communications equipment
(transmitters) and the EUT as recommended below, according to the maximum output power of the
communications equipment.
Rated maximum
output power of
transmitter
W
0.01
0.1
1
10
100
For transmitters rated at a maximum output power not listed above, the recommended separation
distance d in metres (m) can be estimated using the equation applicable to the frequency of the
transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to
the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected
by absorption and reflection from structures, objects and people.
16
Table 2 – continued
Separation distance according to frequency of transmitter
m
150 kHz to 80 MHz
3.5
=
d
P
3
0.2
0.4
1.2
3.7
11.7
CELSIUS (Med) / ESPRIMO (Med)
80 MHz to 800 MHz
3.5
=
d
P
3
0.2
0.4
1.2
3.7
11.7
800 MHz to 2.5 GHz
7
=
d
P
3
0.4
0.8
2.4
7.4
23.4