Mounting of the heating element (optional)

• Position the heating element in the Cryo insulation box.
• Make sure that the heating element is positioned on both sides of the transducer box (see Fig. 3.15).
For the mounting and the connection of the heating element see the delivered manufacture's documents. Observe the sa-
fety instructions!
• Press the connection cable with the cable gland into the notch on the side panel of part B of the Cryo insulation box (see
Fig. 3.16).
Attention!
If the temperature of the fluid in the pipe is lower than the minimum operating temperature specified
for the transducer heating system, this system has to be switched on.
For the operating temperature range of the transducer heating system see the provided documents of
the manufacturer.
38
tension strap
slot
screw
Fig. 3.14: Mounting of the tension strap
bigger notch
connection cable
Fig. 3.15: Mounting of the heating element
Fig. 3.16: Mounted heating element
Supplement to User Manual - ENGLISH
spread
apart
cable
cable gland
SUFLUXUS_WI_CYOV1-2, 2016-12-16