250/450/550 watt

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 32
NB!
Suction hose and fi lter MUST be fi lled with water. Depending on length and diameter of
the suction hose, reaching full pressure may take some time.
1. Remove transparent fi lter cover.
2. Fill fi lter with clean water.
3. Make sure that the suction hose is fi lled with water and that the water fl ows freely to the pump.
4. Make sure that the nozzle or tap on the pressurised hose is open so that air can escape as
pressure builds.
5. Start the pump.
6. Switch off the pump when there is a steady fl ow of water.
7.

Safety

Specifi c uses
This pump is specially designed to circulate water in swimming pools. It must not be used to pump
drinking water or food products. It must not be used to pump explosive, infl ammable, aggressive
fl uids or substances which are hazardous to health, or salt water containing more than 4% salt.
This pump is not suitable for commercial or industrial use. Changes to the pump or the use of parts
that are not approved by the manufacturer are strictly prohibited. The manufacturer accepts no lia-
bility for damage caused due to inappropriate use of the pump.

General safety instructions

Never allow children, adolescents and anyone who is not acquainted with these instructions to
operate the pump. Always comply with applicable local regulations regarding water supply and
waste water. The following risks exist in principle when using any pump or pressurised container.
They cannot entirely be eliminated – even when safety devices are used.
Hazards caused by immediate surroundings!
• Should not be exposed to persistent rain.
• Should be placed on a fi rm and even surface, which is dry and well-drained.
• Never place the pump in the vicinity of infl ammable liquids or gases.
DANGER Risk of electric shock!
• Never aim a jet of water directly at the pump or other electrical parts! Risk of fatal electric shock!
• Never touch the electrical plug if your hands are wet! To disconnect, pull on the plug – not on the
cable.
• The earthed plug or the plug's connection to an extension lead must be placed in an area that
is not subject to fl ooding.