water. A dry run will damage the pump!
NB!
Suction hose and filter MUST be filled with water. Depending on length and diameter of
the suction hose, reaching full pressure may take some time.
1. Remove transparent filter cover.
2. Fill filter with clean water.
3. Make sure that the suction hose is filled with water and that the water flows freely to the pump.
4. Make sure that the nozzle or tap on the pressurised hose is open so that air can escape as
pressure builds.
5. Start the pump.
6. Switch off the pump when there is a steady flow of water.
7.

Safety

Specific uses
This pump is specially designed to circulate water in swimming pools. It must not be used to pump
drinking water or food products. It must not be used to pump explosive, inflammable, aggressive
fluids or substances which are hazardous to health, or salt water containing more than 4% salt.
This pump is not suitable for commercial or industrial use. Changes to the pump or the use of parts
that are not approved by the manufacturer are strictly prohibited. The manufacturer accepts no lia-
bility for damage caused due to inappropriate use of the pump.

General safety instructions

Never allow children, adolescents and anyone who is not acquainted with these instructions to
operate the pump. Always comply with applicable local regulations regarding water supply and
waste water. The following risks exist in principle when using any pump or pressurised container.
They cannot entirely be eliminated – even when safety devices are used.
Hazards caused by immediate surroundings!
• Should not be exposed to persistent rain.
• Should be placed on a firm and even surface, which is dry and well-drained.
• Never place the pump in the vicinity of inflammable liquids or gases.
DANGER Risk of electric shock!
• Never aim a jet of water directly at the pump or other electrical parts! Risk of fatal electric shock!
• Never touch the electrical plug if your hands are wet! To disconnect, pull on the plug – not on the
cable.
• The earthed plug or the plug's connection to an extension lead must be placed in an area that
Side 4