CONNECTION OF FUME EXHAUST VENT
Important
Make the connection in compliance with
the relevant legal requirements, using ap-
propriate and recommended materials.
Connecting to a flue with natural draught
To carry out this operation, proceed as follows.
1 - Connect the appliance's exhaust outlet to the
flue (A) using a line complying with the dimen-
sions shown in the diagram.
B
CONVERSION OF GAS SUPPLY
The constructor has tested the appliance with its
own mains gas, identified by the sticker applied to
the nameplate.
If the type of gas to be connected is different from
that used for testing, proceed as follows.
1 - Turn off the gas supply tap (A).
2 - Change the burner nozzle (see page 22).
3 - Change the pilot light nozzle (see page 23).
4 - Adjust the minimum settings of the gas control
valves of the burners (see page 20).
5 - Remove the sticker from the nameplate and ap-
ply the new one to identify the gas being used.
Important
On completion of the operation, make sure
that there are no gas leaks or malfunctions.
Connecting to a fan extractor hood
To carry out this operation, proceed as follows.
2 - Position the appliance underneath the hood (B)
and connect a line of the dimensions shown in
the diagram to the appliance's exhaust outlet.
Important
The fan of the extraction system must
switch on automatically when the gas sup-
ply tap is turned on.
A
A
- 19 -