2 Fitter settings table
Parameter
Press
number
and
PROG
0
for 5 sec.
PROG
1.
PROG
2.*
PROG
3.
PROG
4.
PROG
5.
PROG
6.*
PROG
7.
PROG
8.
PROG
9.
PROG
10.
PROG
11.
PROG
12.
PROG
13.
PROG
14.
PROG
15.
PROG
16.
PROG
17.
* The line is displayed only when the relevant boiler, option, circuit or sensor is actually connected.
(1) Not activated on GMR1000-GVX100-24Condens
(2) GMR1000: Only Boiler pump
19/07/07 - 300010273-001-A
Description
Radio reception level
Boiler temperature measurement
Measurement, outlet temperature B
Gradient of the heating circuit A
Gradient of valve circuit B
Maximum heating circuit temperature A
Maximum temperature of valve circuit B
Automatic adaptation and allocation of the room sensor.
Automatic adaptation is only possible for the circuit with
room sensor (only when the Easymatic control module is
used as a room sensor).
Influence of the room sensor (only when the RS100R
control module is used as a room sensor)
Choice of Night Reduced or Night Stop mode (only with
influence room sensor = 0 )
Antifreeze room temperature setting (only with room sensor
influence other than 0)
Outside temperature set for antifreeze
Domestic hot water priority (only with dhw tank)(1)
Protection against legionnella (only with dhw tank)
Timeout for stopping heating and domestic hot water
pumps(2)
Control number of the remote control memory
Control number of the memory of the central processing
unit
Control memory number of the transmitter/receiver box
Factory setting
1.5
0.7 - 0
75 °C
50 °C
1A
3
1
6 °C
3 °C
1
0
4 mn
RS 100 R
Range of adjustment
0: no reception (may appear for a few
/
seconds)
10: Very good reception
/
/
/
/
0 - 4
40 - 90 °C
40 - 90 °C
1A: Room temperature sensor for
circuit A,adaptation enabled
0A: Room temperature sensor for
circuit A,adaptation blocked
1B: Room temperature sensor for
circuit B,adaptation enabled
0B: Room temperature sensor for
circuit B, adaptation blocked
0 - 10
0 = night stop
1 = night low
5 - 20 °C
-8 - +10 °C
0 = non priority
1 = priority
0 = deactivated
1 = activated
0 - 10 mn
/
/
/
/
/
/
9