2 Pairing (to be done in the boiler room when installing for the first time)
Each remote control includes a unique factory-allocated identification
number, which enables the transmitter / receiver box to recognize the
remote control attributed to it. This identification number is
transmitted to the transmitter / receiver box by the pairing sequence
described below:
- Press the button on the transmitter / receiver box using a pen.
- Press simultaneously on keys PROG
remote control.
- The light on the transmitter / receiver box lights up and the text
"connect" is displayed.
- After a few seconds, the light on the transmitter / receiver box
goes out and the remote control displays the message "init" for a
few seconds to synchronize all data from the transmitter / receiver
box (synchronization).
- After a few seconds, the message disappears and the current
display reappers (times, minutes), alternatly with the outside
temperature if an outside sensor is connected.
- If a problem occurs, the light starts to flash after 2 minutes and/or
the remote control displays the message AL rf.
- If the light flashes or the message AL rf appears, the transmitter /
receiver box is not paired. Repeat the pairing sequence.
This operation does not have to be done again after
changing the batteries.