4 Set-up

3.3 CE marking

The CE mark shows that the products
comply with the basic requirements of the
applicable guidelines as stated on the data
plate.
The manufacturer hereby declares that the
type of radio equipment that is described
in these instructions complies with Direct-
ive 2014/53/EU. The complete text for the
EU Declaration of Conformity is available
at: http://www.vaillant-group.com/doc/doc-
radio-equipment-directive/.
Frequency band: 863–870 MHz
Maximum transmission power: < 25 mW
4 Set-up

4.1 Checking the scope of delivery

Check that the scope of delivery is com-
plete.
Quant-
Contents
ity
1
Front panel
1
Wind protection
1
Wall-mounting frame
1
Fan unit
1
Regenerator with two filters
1
Operating instructions
1
Installation instructions
38

5 Installation

5.1 Observing the requirements for
the product's installation site
The product can be installed in flats, cellar
rooms, storage or utility rooms, and in at-
tics.
Observe the current applicable national
construction regulations.
Ensure that the installation site is dry
and is frost-proof throughout.
When determining the installation site,
take into consideration the product's
sound power level and sound reduction
index.
– → Technical data in the appendix
Take into consideration the diameter of
the pipe and the minimum clearances to
ceilings, windows and corners.
5.2 Installing the pipe from the pre-
installation set
1. Insert the pipe from the pre-installation
set into the designated position on the
external wall.
– In doing so, observe the set-up in-
structions that are enclosed with the
product.
2. Ensure that the power supply cable
and the control cable are not damaged
when you drill through the wall.

5.3 Installing the outer hood

Install the outer hood and its wall-
mounting frame.
– In doing so, observe the set-up in-
structions that are enclosed with the
product.
– Use suitable rawl plugs and flat-head
screws.
Installation instructions recoVAIR 0020236694_04