Energy Saving Advice; Diagnosis Of The Problems; Functional Aspects Not To Be Interpreted As Problems - Olimpia splendid UNICO Handbuch Für Installation, Gebrauch Und Wartung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 77
3.3.18
Controlling the UNICO BOILER WALL unit from the console
Description of the console
L1
or in operating conditions that prevent the heat pump from working. A red light off means the water has reached the required water
Buttons (Fig. 43)
T1
UNICO BOILER WALL On button.
T2
and Turbo2 (TURBO1 and TURBO2 icons lit up).
T3
MASTER and WALL).
T5
PLUS button increases the required water temperature setting.
T6
MINUS button decreases the required water temperature setting.
T7
Button reserved for the installer for setting operating parameters.
Display (Fig.43)
D1D2
Required water temperature in degrees centigrade.
S1
S2
S3
up it is the normal operating temperature.
S4
S5
K4
Icon lit up during the water heating phase for Anti-legionella function.
Turning the appliance on and off
is always in heating mode (icon S2 lit up) and automatically heats up the water each time the temperature set and showing on the
The system for controlling the appliance is equipped with a memory so all the settings will not be lost when the unit is switched off.
TURBO1 and TURBO2 functions
BOILER WALL electric heating element to further reinforce the production of hot water.
ANTIFREEZE function
the water (by means of the electric heating element) to a temperature that will prevent ice from forming. The Antifreeze function
activates even if the unit is in Standby.
BACKUP function
ANTI-LEGIONELLA function
Periodic heating up of the water stored can be programmed in order to prevent bacteria from forming. The Anti-legionella function
3.4

ENERGY SAVING ADVICE

-
Keep the doors and windows closed in the air-conditioned rooms.
3.5

DIAGNOSIS OF THE PROBLEMS

It is important for the User to distinguish between functional problems and anomalies in relation to the behaviour of the appliance
Olimpia Splendid Service Centre.
WARNING: Please remember that any attempt to repair the appliance by unauthorised personnel will immediately invalidate
any form of guarantee.
3.5.1

Functional aspects not to be interpreted as problems

-
The compressor does not start up again immediately after a stop (it takes about three minutes to start again).
that the compressor itself is protected against activations that are too frequent.
compressor has started.
3
53
UNICO BOILER