7. WARNING

Make sure the appliance is disconnected from mains supply before any intervention. Any
intervention shall be qualified and authorised personnel only.

8. RECYCLING THE PRODUCT

Your appliance is reaching the end of its working life. You would like to get rid of it or
replace it. Please do not throw it into the dustbin or into your local council's selective
When this symbol appears on a new appliance, it means that the equipment must not
be thrown away and that it will be collected selectively so that it can be reused,
recycled or recovered. Any substances it may contain which are potentially
You can give it to a community association who will be able to repair it and put it back into circulation.
If you buy a new one, you can take the old one to the store or ask the delivery man to take it back.
Otherwise please take it to a waste collection centre, if your local council has set up a selective
GIVE THE APPLIANCE
TO A COMMUNITY

9. ELECTRIC DIAGRAM HEAT LINE+

ELIMINATION OR SHUNTING OF ONE OF THE SAFETY OR REMOTE CONTROL ORGANS LEADS
AUTOMATICALLY TO THE CANCELLATION OF THE GUARANTEE
With an aim to improving its products, ZPCE reserves the right to modify the characteristics
without prior notice
dangerous to the environment will be eliminated or neutralised.
This is known as a "One-for-One" exchange.
collection system for these products.
TAKE THE USED DEVICE BACK TO
THE DISTRIBUTOR WHEN MAKING A
NEW PURCHASE
Regulator with digital display
IMPORTANT!
sorting containers.
NB: do not admit any long
extension or multisocket
connection.
black or
grey sheath
Electronic connections:
CA: supply cable: 2P+T 10/16A 3G1
Voltage: 230V-1N-50Hz
: Earth
19-20: dry control contact "normally open"
8
TAKE THE USED DEVICE
TO A WASTE
LEGEND:
CD: flow rate controller
F1: protection fuse 3,15 A-T
L1: "on/off" led
L2: "reg" led timed flashing or
permanently - heating in progress
M1: circulator motor
S1: "on/off" switch
So: Pool water regulation probe
TH: control thermostat with digital
display
V-j: green-yellow
Bl: blue
M: brown
B: white
N: black
- Edition 01/2009