Herunterladen Inhalt Inhalt Diese Seite drucken

Diagnostic Test 3 - Calibrate Diagnostic Test; Calibrate The Lift Arm - Rimage Producer III 6100 Benutzerhandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 25
Rimage Producer™ III User Guide
Manually, slowly move the lift arm and disc down into the bin. Make sure that the disc does not interfere with the
6.
carousel as it moves into the bin.
-
Important! If the disc interferes with the carousel in step 7, the lift arm may be miscalibrated or there may be an
issue with the hardware that positions the carousel. Perform diagnostic test 3 (Calibrate Diagnostic Test) on page 18
to calibrate the lift arm and the carousel.
Manually move the lift arm out of the bin.
7.
Repeat steps 6 - 8 for the remaining bins.
8.
Press the disc release button to release the disc and remove it from the lift arm.
9.
Press and hold the operator button to exit the test and return to diagnostic mode.
10.
Refer to the
11.
Exit Diagnostic Mode
Diagnostic Test 3 – Calibrate Diagnostic Test
This test has two modes. The first mode calibrates the lift arm to accurately detect the number of discs in the carousel bins.
The second mode calibrates the carousel.
-
Important! If you are updating the autoloader firmware, you must prompt the system to run the carousel calibration
test immediately after the lift arm calibration test.

Calibrate the Lift Arm

This test calibrates the lift arm to accurately detect the number of discs in the carousel bins.
Remove all discs from the carousel bins.
1.
Make sure that the autoloader is in diagnostic mode. Refer to the
2.
Press the operator button three times and hold on the third press until the operator panel displays [03 CALIBRATE].
3.
Release the operator button. The lift arm moves to the top position and the light on the operator button flashes.
4.
-
Important!
If you are updating the autoloader firmware, you must prompt the system to run the carousel calibration test
immediately after the lift arm calibration test. Move the lift arm to the top of the lift column at this time and
then continue to step 5.
If you want to proceed with the lift arm calibration test only, continue to step 5 at this time.
Place one disc in bin 1.
5.
-
Important! Place only one disc in bin 1.
Tip: If you need to rotate the carousel to load media into bin 1, rotate it manually. Pressing the operator button
prompts diagnostic test 3 to begin.
18
7100N/8100N/6100N/6100
section on page 17 to exit diagnostic mode.
Access and Select Diagnostic Tests
section on page 16.
2001475_A

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Producer iii 6100nProducer iii 7100n

Inhaltsverzeichnis