Herunterladen Inhalt Inhalt Diese Seite drucken

YATO YT-85432 Bedienungsanleitung Seite 18

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
NOTE! In case it is necessary to immediately stop the engine due to emergency, the engine switch must be placed at OFF.
Refuelling
NOTE! Do not ever refuel the generator during its operation.
Stop the engine in accordance with the procedure indicated in „Stopping the engine".
Wait at least two minutes until the engine has cooled down.
Fill fuel in accordance with the indications in „PREPARATIONS FOR OPERATION".
Close the fuel inlet tightly.
Start the generator again in accordance with the procedure indicated in „ Start-up of the internal combustion engine".
If the fuel level is too low, the engine will stop automatically.
MAINTENANCEA AND INSPECTIONS
During the warranty validity period the user must not dismantle the device or replace any subassemblies and elements of the
device, since this would make the warranty void. Any irregularities observed during inspections or operation of the machine con-
stitute an indication the device must be repaired at a service shop.
Once operation has concluded, the housing, the ventilation openings, the switches, the additional handle and the protections
must be cleaned, for example with air jet (whose pressure must not exceed 0.3 MPa), a brush or a dry cloth, without any chemical
substances or cleaning agents. The tools and handles must be cleaned with a dry, clean cloth.
Periodical revisions
It is required to carry out periodical revisions and maintenance of the following subassemblies of the generator.
NOTE! All maintenance actions must be realised when the device is turned off and not functioning. It is also required to disconnect
any electrical devices from the generator.
NOTE! If any service action is not described below, then the in order to have the action in question carried out, the device must
be sent to a specialist service shop.
NOTE! If the device is cleaned with a solvent, any contact of the solvent with the skin and the eyes must be avoided. Use personal
protection means.
Element
Remarks
Revision of the condition of
Spark plug
electrodes. If necessary, replace
them
Air filter
Check. If necessary, clean it
Fuel inlet filter
Cleaning. If necessary, replace it
Revision of tightness and possible
Fuel system
damage. If necessary, replace it
Check tightness. If necessary,
replace the gaskets
Exhaust system
Exhaust muffle screen
Check the condition of the fuel
Carburettor
valve lever
Check the condition of the
Cooling system
ventilator
Cleaning. If necessary replace
Fuel filter cover
the gasket
Starting system
Check the starting system
Removal of carbon
Check with more frequency, if
residues
necessary
Connections and fixing
Check all the connections and
elements
fixing elements
Cleaning and adjustments of the
Engine
valves and cylinders
Oil
Replacement
O R I G I N A L
18
GB
Every month or every
Before each start-up
20 hours of operation
X
X
X
X
X
X
I N S T R U C T I O N S
Every 6 months or
Every 12 months or
every 100 hours of
every 300 hours of
operation
operation
X
X
X
X
X
X
X
X

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Yt-85434Yt-85437Yt-85440

Inhaltsverzeichnis