Herunterladen Inhalt Inhalt Diese Seite drucken

Dwell Measurements; Rpm Measurements; Continuity Test And Diodes; Electrical Specifications - USAG 075 F Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 36

DWELL measurements

• Position the rotary switch in the DWELL section, by selecting the number of
cylinders according to the number of cylinders of the motor being tested.
• Connect the black cord to the "COM" bushing.
• Connect the red cord to the "INPUT" bushing.
• Take the measurement according to the diagram in figure page 78.

RPM measurements

• Position the rotary switch in the TACH section, by selecting the number of
cylinders according to the number of cylinders of the motor being tested.
• Connect the black cord to the "COM" bushing.
• Connect the red cord to the "INPUT" bushing.
• Take the measurement according to the diagram in figure page 79.
Continuity and diode test
• Position the rotary switch on: "
• Connect the black lead to the "COM" bushing.
• Connect the red lead to the "INPUT" bushing (the polarity of the red lead is
positive).
• Press the "FUNC" push-button to select the measurement mode "
or "
"
• If the continuity test is selected, connect the leads as shown in figure page 76.
If there is a continuity, the buzzer will beep.
• If the diode test is selected, connect the leads as shown in figure page 76 and
take the measurement.
N.B.: never connect the leads directly to a source of voltage.

ELECTRICAL SPECIFICATIONS

Volt DC
Range
20 0 m V
2V
20 V
20 0 V
60 0 V
Input impedance:
Protection:
Maximum input voltage: 600V AC RMS
" continuity test / "
Resolution
0,1mV
0,001 V
0,01V
0,1V
1 V
10M
capacity 200mV up to 250V DC/AC RMS
capacity:
2V to 600V up to 600V DC/AC RMS
20
" diode test.
Accuracy
± 0 , 7% rdg + 2 d i g i t
± 0 , 7% rdg + 2 d i g i t
± 0 , 7% rdg + 2 d i g i t
± 0 , 7% rdg + 2 d i g i t
± 0 , 7% rdg + 2 d i g i t
"