Display
Flat battery
Measurement in auto-range
AUTO
Enabled memorya
DATA-H
Enabled memory (max. value)
MAX-H
Degrees centigrade
ºC
Degrees Fahrenheit
ºF
Diode test
Continuity test
DC measurement
DC
AC measurement
AC
Measured quantity
V - mV
Measured quantity
A
Measured quantity
- k - M
DWELL
Revolutions per minute
RPM
Polarity indication
Multiply the read value x10
x10

Technical specifications

• Insulation class: 600V CAT.III pollution degree 2
• Working temperature: 0 to 40°C / 32 to 104°F <80% RH
• Storage temperature:-10 to +50°C / 10 to 122°F
• Precision: see the specifications on page 32
• Maximum ground voltage: 600V DC/AC
• Frequency response: 40 - 400 Hz
• Electronic protection for all capacities
• Ramp time: 0,4sec
• Display: 3
1
/
LCD (16 mm) 1999 dots with automatic indication of functions and
2
symbols
• Automatic/manual selection di capacity
• Automatic flat battery signal
• Automatic polarity signal
• Automatic switchoff: automatic turning off of the instrument, when switched
on, after approx. 15 minutes.
• Power supply: 3 batteries, 1.5V AAA
• Dimensions: 158x74x32 mm
• Weight: 250 g (including batteries)
Preparing the measurement
Position the rotary switch on the selected function. If the "
replace the battery.
<80% RH