alt and brief inversion
alt and inversion
alt in closing
In this command category the user can select one of the operating modes specified in Table 1-M.
OPERATING MODE
alt
alt and brief inversion
alt and inversion
obstacle detection in opening
In this command category the user can select one of the operating modes specified in Table 1-N.
OPERATING MODE
alt
alt and brief inversion
alt and inversion
obstacle detection in closing
In this command category the user can select one of the operating modes specified in Table 1-O.
OPERATING MODE
alt
alt and brief inversion
alt and inversion
14 – Robus 600-1000
Operating mode set in factory. When the control unit
receives the command, it stops the Opening manoeuvre in
progress immediately and activates the application to perform
a brief inversion in the opposite direction (Closing).
When the control unit receives the command, it stops the
Opening manoeuvre in progress immediately and activates the
application to perform a total inversion in the opposite direc-
tion (Closing).
TABLE 1-M: COMMAND CONFIGURATION
DESCRIPTION
When the control unit receives the command, it stops the
Closing manoeuvre in progress.
Operating mode set in factory. When the control unit
receives the command, it stops the Closing manoeuvre in
progress immediately and activates the application to perform
a brief inversion in the opposite direction (Opening).
When the control unit receives the command, it stops the
Closing manoeuvre in progress immediately and activates the
application to perform a total inversion in the opposite direc-
tion (Opening).
TABLE 1-N: COMMAND CONFIGURATION
DESCRIPTION
When the control unit receives the command, it stops the
Opening manoeuvre in progress.
Operating mode set in factory. When the control unit
receives the command, it stops the Opening manoeuvre in
progress immediately and activates the application to perform
a brief inversion in the opposite direction (Closing).
When the control unit receives the command, it stops the
Opening manoeuvre in progress immediately and activates the
application to perform a total inversion in the opposite direc-
tion (Closing).
TABLE 1-O: COMMAND CONFIGURATION
DESCRIPTION
When the control unit receives the command, it stops the
Closing manoeuvre in progress.
When the control unit receives the command, it stops the
Closing manoeuvre in progress immediately and activates the
application to perform a brief inversion in the opposite direc-
tion (Opening).
Operating mode set in factory. When this type of function is
set, when the control unit receives the command, it stops the
Closing manoeuvre in progress immediately and activates the
application to perform a total inversion in the opposite direc-
tion (Opening).