In this command category the user can select one of the operating modes specified in Table 1-B.
OPERATING MODE
Open - Stop - Close - Stop
Open - Stop - Close - Open
Open - Close - Open - Close
Apartment block 1 step step
Apartment block 2 step step
Hold-to-run
Industrial mode
open
In this command category the user can select one of the operating modes specified in Table 1-C.
OPERATING MODE
Open - Stop - Open
Apartment block 1
Apartment block 2
Open 2
Hold-to-run Open
close
In this command category the user can select one of the operating modes specified in Table 1-D.
OPERATING MODE
Close - stop - close
TABLE 1-B: COMMAND CONFIGURATION
DESCRIPTION
Operating mode set in factory. This executes the above
sequence.
This executes the above sequence.
This executes the above sequence.
This executes the sequence "close - stop - partial open 1-
partial open 1" until the maximum position is reached as pro-
grammed in the function "Partial Open 1". Note – If another
command is sent after this one, the application executes the
Closing manoeuvre with the same sequence.
This executes the sequence "close - stop - partial open 1 -
partial open 1" until the position is reached as programmed in
the function »Partial Open 1". Note – If another command is
sent after this one, the application executes the Closing ma -
noeuvre with the same sequence.
Important – When sending a command, if the transmitter key
is held down for more than 2 seconds, the control unit acti-
vates a Stop.
The Partial open 1 or Closing manoeuvre is executed exclu-
sively if the transmitter key is held down (hold-to-run)..
This executes the sequence "open in semi-automatic – close
in hold-to-run".
TABLE 1-C: COMMAND CONFIGURATION
DESCRIPTION
Operating mode set in factory (Input 2 - "open" com-
mand). This executes the above sequence.
This executes the sequence "open - open".
Important – When sending a command, if the transmitter key
is held down for more than 2 seconds, the control unit acti-
vates a Stop.
This executes the Opening sequence. Important – When
sending a command, if the transmitter key is held down for
more than 2 seconds, the control unit activates a "partial open
1" command (input configuration > Table 1).
The Opening manoeuvre is executed exclusively if the trans-
mitter key is held down (hold-to-run).
TABLE 1-D: COMMAND CONFIGURATION
DESCRIPTION
Operating mode set in factory (Input 3 - "close" comma -
nd). This executes the above sequence.
Robus 600-1000 – 11