TABLE 1
Light Condition
Steady Green
System O.K. Power source
comunicating normaly with wire
feeder.
Blinking Green
Occurs during a reset, and indicates
the power source is mapping
(identyfying) each component in the
systems. Normal for first 1-10
seconds after power is turned on, or
if the system configuration is
changed during operation.
Alternating
Non-recoverable system fault. If the
Green and Red
PS status light is flashing any
combination of red and green, errors
are present in power source.
Individual code digits are flashed in
red with a long pause between digits.
If more then one code is present, the
codes will be separated by green
light. Read the error code before the
machine is turned off.
If occurs, to clear the error try to turn
Off the machine, wait for a few
seconds, then turn ON again. If the
error remains, a maintenance is
required. Please contact the nearest
technical service center or Lincoln
Electric and report the error code
readed.
Steady Red
Non recoverable hardware fault.
Generally indicates nothing is
connected to the power source wire
feeder receptacle.
Blinking Red
Not applicable.
3.
Thermal Indicator Light: It indicates that the
machine is overloaded or that the cooling is not
sufficient.
4.
Negative Output Socket: For connecting the return
welding cable.
5.
Control Socket: 5 pins receptacle for wire feeder or
remote controller connection. To communication
wire feeder with power source is used ArcLink
protocol.
6.
Positive Output Socket: Allows the connection, with
the power cable, to the wire feeder.
English
Meaning
7.
Gas Heater Socket: U
8.
Fuse Socket F3: The recommended fuse
12,5A/400V (6,3x32mm).
You have to use fuses with technical specifications
given by the producer.
9.
Fuse Socket F4: The recommended fuse
6,3A/400V (6,3x32mm).
You have to use fuses with technical specifications
given by the producer.
10. Fuse Socket F1: The recommended fuse 2A/400V
(6,3x32mm).
You have to use fuses with technical specifications
given by the producer.
11. Fuse Socket F2: The recommended fuse 2A/400V
(6,3x32mm).
You have to use fuses with technical specifications
given by the producer.
12. Power Input Cable: Connect the proper plug to the
input cable then into the rated output according to
appropriate rules. Only qualified personnel shall
connect this plug.
13. Cooler Power Supply Socket: The socket has an
output of 400VAC to supplying water cooler (it is
protected by the circuit breaker [10]).
Read and understand the cooler manual before
connecting it to the machine.

Welding Cables Connections

Insert the plug of the work cable into the socket [4]. The
other end of this cable connects to the work piece with
the work clamp.
3
= 24VAC, P
= 80W.
sup
max
WARNING