4-3. Wiring System Diagrams

■ Europe
L
Power supply
N
220/230/240V ~ 50Hz
Ground
Remote
controller
WHT
1
1
BLK
2
2
L
Power supply
N
220/230/240V ~ 50Hz
Ground
■ Oceania
L
Power supply
N
230/240V ~ 50Hz
Ground
Remote
controller
WHT
1
1
BLK
2
2
L
Power supply
N
230/240V ~ 50Hz
Ground
NOT E
(1) Refer to Section "4-2. Recommended Wire Length
and Wire Diameter for Power Supply System" for the
explanation of "B", "C", "D" and "E" in the above diagram.
(2) The basic connection diagram of the indoor unit shows the
terminal boards, so the terminal boards in your equipment
may differ from the diagram.
(3) Refrigerant Circuit (R.C.) address should be set before
turning the power on.
(4) Regarding R.C. address setting, refer to the installation
instructions supplied with the remote controller (Optional).
Auto address setting can be executed by remote controller
automatically.
Indoor unit
(No. 1)
L
N
SG
B
U1
U2
D
R1
R2
Indoor unit
(No. 2)
L
N
SG
B
U1
U2
E
R1
R2
Indoor unit
L
N
SG
B
U1
U2
D
R1
R2
Indoor unit
L
N
SG
B
U1
U2
R1
R2
(SG : Shows the ground for the shielded cable.)
* 3-phase model connections
Outdoor unit (3-phase)
INV unit
C
L1
U1
L2
U2
L3
N
SG
C
* Single-phase model connections
Outdoor unit (single-phase)
INV unit
L
N
U1
U2
SG
* 3-phase model connections
Outdoor unit (3-phase)
INV unit
C
L1
U1
L2
U2
L3
N
SG
* Single-phase model connections
Outdoor unit (single-phase)
INV unit
C
L
N
U1
U2
SG
4P terminal board
U1
Unit
control
line
14
L1
Power supply
L2
380/400/415V, 3 N~, 50Hz
L3
N
Ground
L
Power supply
220/230/240V ~ 50Hz
N
Ground
L1
Power supply
L2
400/415V, 3 N~, 50Hz
L3
N
Ground
L
Power supply
230/240V ~ 50Hz
N
Ground
U2
R1
R2
Remote
control
line
Type U2
2P terminal board
L
N
Power
supply

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis