The metal shielding must not be shortened by the customer.
If the (blue) high-voltage cable has to be shortened, used in the MEB, MEJ, EP-SH-N,
P-SH-N(2) bars, this must be carried out as specified in the sketch below.
Warning:
− Do not damage the transparent PE insulation underneath!
The high-voltage cable for the MaxION, QMC and SS bars can be stripped in the usual way.
6. Putting into use
The anti-static bar is put into operation by switching on the power unit.
7. Functional check
A SIMCO bar checker can be used to verify that the high voltage at the emitter points is on.
An electrostatic fieldmeter must be used to measure the efficiency of the anti-static bar.
Measure the charge on the material before and after it has passed the anti-static bar.
The charge measured should have disappeared after the material has passed the anti-static
bar.
8. Maintenance
Warning:
− When carrying out work on the equipment: de-energise the equipment.
Attention:
− Do not damage the emitter points.
− Keep the anti-static bar clean.
− If fouled: Clean the anti-static bar with a hard non-metal brush.
(Brush: Simco item no. 2000430001)
− If heavily fouled: clean anti-static bar with isopropyl alcohol or with Veconova 10 industrial
cleaner (www.eco-nova.nl) (not for anti-static bar MSB)
− Allow the anti-static bar to dry entirely, before energising again.
Staven 97.52.03.90.10
Blue PVC coating removed
7
7
+/- 2
47
Shielded HV - cable
16
08/08