INSTALLATION OF THE HOT WATER TANK AND HEATING PUMP
The hot water tank with heating pump can be installed in
in a dry room where it is not freezing, possibly in the
vicinity of other sources of heating, with the temperature
ranging from 10 to 35 °C and no larger than 20 m
Generally, we suggest a large enough and well-
ventilated room with the temperature ranging between
15 and 25 °C, which represents optimal conditions for
the operation of the heating pump. When selecting the
room for installing the hot water tank and heating pump,
one should make certain that the selected room is not
too exposed to dust, because dust has adverse effects
on the efficiency of heating pumps.
To prevent pressure depression in the building, fresh air
must be regularly supplied to the premises. The desired rate of air exchange for a
residential building is 0.5. This means that the entire quantity of air in the building is
exchanged every two hours.
During the operation of the heating pump, condensate is formed in within the aggregate. It
must be led into the sewage by means of a flexible condensate drainpipe 16 mm on the
backside of the heat pump. The quantity of condensate depends on air temperature and
humidity.
To reduce the transfer of noise and vibrations of the built-in fan, please take the following
measures to prevent the transfer of noise and vibrations through the walls into premises
where this would be disturbing (bedrooms, rooms intended for resting):
- install flexible joints for hydraulic connections
- plan insulation to prevent floor vibrations
- use positioning feet.
OPERATION OF THE HEATING PUMP
After the water tank with heating pump is connected to water supply (heating) network and
filled with water, the heating pump is connected to power supply network and ready for
operation. The appliance should be connected to the power supply network in compliance
with the national installation regulations.
Legend:
1 - Electronic regulator
2a - Temperature sensor -
surroundings
2b - Temperature sensor -
boiler
3 - Motor of the fan
4 - Thermal protection
5 - Compressor
6 - Operating condenser
7 - Thermal cut-out
8 - Connection terminal
L - Live conductor
N - Neutral conductor
- Earthing conductor
L
230 V~
50 Hz
N
Electric installation
min 20 m
3
.
min 0,5 m
3
min 1 m
15