Herunterladen Inhalt Inhalt Diese Seite drucken

Interconnection Diagram - Siemens XLT-30 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 23

Interconnection Diagram

NON - HAZARDOUS LOCATION
(SAFE)
CONTROLLER
CONTROLLER
NOTE :
1) THE TRANSDUCER CABLE MUST BE TERMINATED IN AN AREA EXTERNAL
TO HAZARDOUS LOCATIONS, CLASS I & II GR. A,B,C,D,E,F,G
2) A SEAL SHALL BE INSTALLED WITHIN 50 mm OF THE TRANSDUCER CONDUIT HUB.
3) THE TRANSDUCER DOES NOT HAVE AN INTERNAL GROUNDING PROVISION.
IT SHALL BE GROUNDED WITH THE EQUIPMENT.
4) INSTALLATION SHALL BE DONE IN ACCORDANCE WITH
CEC PART 1 REQUIREMENTS.
SIEMENS CANADA LIMITED
SIEMENS MILLTRONICS
PROCESS INSTRUMENTS
PETERBOROUGH, ONTARIO, CANADA
Page EN-12
XLT Series Transducers – OPERATION MANUAL
SIEMENS
CERTIFIED
CONDUIT
SEAL
FITTING
SIEMENS
CERTIFIED
CONDUIT
SEAL
FITTING
Product Group
ULTRASONICS
21 DEC.1995
B. GRAY
S. NGUYEN
TIEN VU
PETERBOROUGH
FOR INTERNAL USE ONLY
00027101
HAZARDOUS LOCATION
CSA CLASS I, GROUP A,B,C,D
CSA CLASS II, GROUP E,F,G
METAL CONDUIT
CERTIFIED
CONDUIT
FITTING
JUNCTION BOX
CLASS I & II
METAL CONDUIT
COAXIAL
CERTIFIED
CONDUIT
FITTING
NON COAXIAL
REVISED TITLE BLOCK PER ECO P5A00004758
1
REMOVED MILLTRONICS REFERENCE
0
FOR RELEASE
XLS/XLT TRANSDUCER SERIES
INTERCONNECTION DIAGRAM
0-8830004Z-DI-A
1 : 1
SEAL
XLS/XLT SERIES
TRANSDUCER
SEAL
XLS/XLT SERIES
TRANSDUCER
MC
PJF
BG
TV
NTS
1
1
A5E32280448
JULY
03/2012
DEC
21/95
A
1

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis