F- THINGS THAT MUST BE DONE BEFORE CALLING AUTHORIZED

SERVICE

Troubleshooting

The failures and solutions stated in this section can be performed easily by yourselves and always consult to
an Authorized Uğur Service if these suggestions do not solve your problem.
CAUTION!
Intervention to any failure that may occur in your product must be carried out by Authorized Uğur Ser-
vice.
Any intervention that may be done by you may harm you, your employee or customer, invalidate the
product guarantee and cause material damage (fire etc.).
In case of any failure, consult to Uğur Customer Care or Authorized Uğur Service.
Troubleshooting
Your product is not working. (No
sound or only fan sound comes from
the product.)
Device internal temperature is high.
Device internal temperature is very
low.
Lamps of the cooler do not light or
only one of them lights.
High degree of sweating on the
glass and inside the device.
Bad smell coming from the bottom
part of your cooler
Power values of the bulbs and leds used in your products are stated in the section where they are
inserted and may vary in products. Only Authorized Uğur Service can intervene bulbs and leds used
in your products.
Possible Solution
It may be due to the thermostat.
Not plugged in.
The fuse may be blown or broken
down.
Condenser lamella may be ob-
structed or get dirty.
External ambient temperature is
very high or wrong thermostat
setting.
Very close to the back wall, ventila-
tion shutters are obstructed or its
front is prevented.
It may have been exposed to exces-
sive external wind.
Condenser lamellas are very dirty.
Wrong internal thermostat setting.
Lamps are turned off.
Bulb has blown or starter failure.
Water discharge hole may be
obstructed when sweating is seen
inside the cabin.
In glass sweating on the other hand,
current external ambient humidity
is over 65%.
Lower water discharge tray is dirty.
45
Result
It will run again when reached to
the suitable temperature.
Insert the plug properly.
Consult to an Authorized Uğur Ser-
vice or a competent electrician.
Clean the condenser lamellas.
Move the cooler to a place where
the external temperature is lower.
Adjust to the stated gap.
Clean in front of the ventilation
shutters.
Prevent the wind.
Clean the condenser lamellas.
Re-set the thermostat.
Turn-on the lamps.
Replace failed part.
Clean water discharge hole. With re-
gards to the high humidity, you can
move your cooler to an environment
with less humidity. Make sure that
the discharge hole is closed when
the product is running.
Clean the water discharge tray.