Herunterladen Inhalt Inhalt Diese Seite drucken

In The Absence Of Controlsystem; Operation; Remote Mode; Manual Mode - Espa SilenPlus ControlSystem Gebrauchsanweisung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 21
4.2.3 Calibrating the ControlSystem
The 6 valve positions must be indicated to the system.
For this purpose, use the following calibration process
(See Figure 3):
1 - Move the valve control to position 4.
Wait for the green LED is illuminated.
2 - Move the valve control to position 6.
Wait for the green LED is illuminated.
3 - Move the valve control to position 2.
Wait for the green LED is illuminated.
4 - Move the valve control to position 5.
Wait for the green LED is illuminated.
5 - Move the valve control to position 3.
Wait for the green LED is illuminated.
6 - Move the valve control to position 1.
The pump will start up in Remote Filtration Plus mode.
The corresponding LED will come on.
4.3 Multiple system
In an installation with several pieces of equipment,
SilenPlus must be started up and the ControlSystem
activated in order.
Each piece of equipment is linked using a unique code
to prevent interference between them.
A SilenPlus pump in standby mode will be linked to the
first ControlSystem activated.
WARNING: activate the ControlSystem of the
valve for the pump on standby.

4.4 In the absence of ControlSystem

If you do not have ControlSystem or prefer not to use it,
the system can work just as well manually.
Ignore the activation and calibration operations, switch
to Manual mode and then connect the SilenPlus.
4.5 Changing the ControlSystem
If it is necessary to replace the ControlSystem in a
system that is already linked, you will need to delete
the old serial number before linking the new one.
To do this, with the SilenPlus pump connected to the
power supply, keep the F button pressed down for 10
seconds. Flashing leds indicate that the operation has
been carried out correctly.
The previous serial number will be deleted and the
system will go into "link standby" mode. Proceed as
indicated in 4.2.2.

5. OPERATION

5.1 REMOTE mode

This is the default operating mode.
The pump carries out the most appropriate function con-
sidering the position of the filter valve. (See figure 3)
In FILTRATION position: Filtration Plus function
• In BACKWASH position: Backwash Plus function
• In CLOSED position: pump stopped.
• In any of the other positions: the pump operates at
100% power.
• When you operate the valve control, the pump
stops automatically to make the valve movement
easier.
• In any intermediate position, the pump remains
stopped.
To change the working mode, simply move the valve
to the desired position.
To prevent accidental operation, the electronic
response is delayed by 1 second. The flashing
red LED indicates that proper communication
has been achieved.
Move the valve gently.
WARNING: the valve configuration must corre-
spond to the 6 standard positions, according to
figure 3.
For other valve configurations, contact your technical
service.

5.2 MANUAL mode

When you press the M key, SilenPlus ignores the Con-
trolSystem signal and runs one of the pre-set functions:
The MAN LED comes on.
The pump starts up at a fixed, programmable speed.
The standard setting is 2,300 RPM (40 Hz). This is
what is known as the MIXED CYCLE (MISC. CYCLE).
If you press the F key, it runs through the various
SilenPlus functions in sequence.
Between each function, the pump stops to allow valve
movement or other operations.
The sequence is:
1. Mixed cycle (MISC. CYCLE).
2. Stop.
3. Filtration Plus.
4. Stop.
5. Backwash Plus.
6. Stop.
7. Mixed cycle...
The lit leds indicates the function selected at all times.
When you press the M button again, you leave Manu-
al mode to go back to Remote.
11
EN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis